background image

Document Number: pnZXTxRM-0712m 

 

 

Page 

 

 

 

1.4  About this Manual 

This manual has been created to assist you in installing, configuring, operating, and trouble shooting 
your Zlinx

®

 Xtreme Radio Modem.  

It is divided into eleven major sections.  
 

Product Information 

 

covers what is included with your radio modem, operating modes, operating 

states, and user interface components.  
 

Hardware Installation 

 

covers how to install your radio modem. Additional information is provided 

about RF considerations, accessory antennas, and cable selection.  
 

Electrical Installation 

 

covers wiring connections and powering your radio modem.  

 

Software Installation 

 

covers installing the manager software and basic software functionality. 

 

Startup and Configuration 

 

contains more detailed information about how to configure your radio 

modem.  
 

Use Cases 

 

contains information concerning the most widely used configurations.  

 

Testing and Troubleshooting 

 

contains information about trouble shooting aids.  

 

Appendix 

 

has additional information.  

 

1.5  Product Features Summary 

 

Need to extend an RS-232/422/485 signal across a highway or across the building?  Your Zlinx 

® 

Xtreme Radio Modem will do the job faster, easier, and less expensively than stringing cable. The 
Zlinx 

®

 Xtreme Radio Modem connects serial devices which can be set up in point to point or point to 

multi point networks. Easy plug-and-play set-up saves installation and maintenance time. In addition, 
Zlinx 

® 

Xtreme Radio Modem meets the IP67 standard and is built to handle the heat, cold, and 

environments of industrial operations. 

 

 

Modbus compatible 

 no additional converters needed 

 

RS-232, 422, 485 (2-Wire & 4-Wire) serial communications 

 

Frequency range: ISM band, 902 to 928 MHz or 2.4 to 2.5 GHz 

 

Signal strength indicators aids troubleshooting. 

 

900 MHz or 2.4 GHz antenna included.  

 

256 Bit AES Encryption 

 

Wide, -40 to 74°C, Operating Temperature 

 

Rugged Circuitry for Indoor and Outdoor Applications 

 

IP67 Rated for total protection against dust and water up to 1 meter 

 

Software support Windows XP, Vista, and 7 (32 / 64 Bit) 

 

Field Upgradable Firmware 

Содержание Zlinx Xtreme ZXT9-RM

Страница 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Страница 2: ...Document Number pnZXTxRM 0712m Page 1 Zlinx Xtreme IP67 Radio Modem ZXT9 RM ZXT24 RM Model Number ZXT9 RM ZXT24 RM...

Страница 3: ...nics Mfg Co Inc No part of this publication may be reproduced or transmitted in any form or by any means electronic or mechanical including photography recording or any information storage and retriev...

Страница 4: ...TS 9 2 5 1 Signal Strength RSSI LED s 9 2 5 2 Transmit LED 9 2 5 3 Receive LED 9 2 5 4 Power LED 10 2 5 5 Internal User Interfaces 10 2 5 6 Push Button 10 2 5 7 USB Connector 11 2 5 8 Terminal Block 1...

Страница 5: ...5 3 2 1 Radio Modem Settings ZXT9 RM 40 5 3 2 2 Radio Modem Settings ZXT24 RM 50 5 3 3 Radio Modem Configuration Screen Off Line 58 5 3 4 Radio Modem Firmware Update Screen 58 5 3 5 Return to Manager...

Страница 6: ...ons 150 B Appendix B Default Configurations 153 B 1 Restore Default Configurations 153 B 2 ZKT9 RM Default Configuration 153 B 3 ZKT24 RM Default Configuration 154 C Appendix C Dimensional Diagram Mou...

Страница 7: ...or Per Terminal Wire Range 30 to 12 AWG Tightening Torque 0 5 to 0 6 Nm Temperature Rating of Field Installed Conductors 105 C minimum sized for 60 C ampacity Please see the Quick Start Guide for UL C...

Страница 8: ...mation about trouble shooting aids Appendix has additional information 1 5 Product Features Summary Need to extend an RS 232 422 485 signal across a highway or across the building Your Zlinx Xtreme Ra...

Страница 9: ...CADA system 2 3 2 Point to Point Serial to Xtreme I O This configuration is employed to connect a PLC HMI SCADA system to a remote Xtreme I O or Zlinx I O module to monitor or control discrete devices...

Страница 10: ...s detected 2 4 4 Sleep State This allows the radio modem to enter a state of low power consumption when not in use 2 4 5 Command Mode Enters AT Command mode with sent to serial input with Guard Time b...

Страница 11: ...plastic Phillips style screws 2 5 6 Push Button Push Button PB1 is located on the circuit board behind the radio modem cover It is used to temporarily set the serial port to a know condition To do thi...

Страница 12: ...It is used to connect a PC to the radio modem to perform configurations and firmware updates The connector is a type b female Any commercially available USB cable can be used to connect to the radio m...

Страница 13: ...85 4 Wire RS 485 2 Wire 4 Wire 2 Wire 1 OFF OFF OFF ON 4 Wire 2 Wire 2 OFF OFF OFF ON Termination Out Termination In 3 OFF OFF OFF OFF RS 422 RS 485 4 OFF OFF ON ON Note The use of built in terminatio...

Страница 14: ...for Class 1 Division 2 applications Please see the Quick Start Guide for UL Class 1 Division 2 installation instructions 3 2 IP67 Cable Gland Installation 3 2 1 Cable Gland Description The Cable Glan...

Страница 15: ...aded side so that it can be attached to the Cable Body 6 Tighten the Cable Nut This will cause the tapered end of the Cable Body to compress ensuring a water tight seal 3 3 Watertight Threaded Conduit...

Страница 16: ...lass 1 Division 2 installation instructions 3 4 1 Description The membrane cable gland is used to plug an unused hole in the enclosure Figure 3 7 IP67 Membrane Cable Gland 3 4 2 IP67 Membrane Cable Gl...

Страница 17: ...ct comes supplied with a rubber duck style antenna which can be articulated up to 90 degrees Then antenna is a wave dipole with an omni directional pattern and vertical polarization It is recommended...

Страница 18: ...directional antennas in outdoor point to multipoint communication Omni Directional antennas are a good choice if you need to mount your antenna on a mast to increase its elevation Please note that mou...

Страница 19: ...na commonly known simply as a Yagi antenna or Yagi is a directional antenna system consisting of an array of a dipole and additional closely coupled parasitic elements usually a reflector and one or m...

Страница 20: ...16 8 inches 42 7 cm Mounting Brackets Included YS8966 High Gain Yagi 900 MHz Use With ZXT9 RM 900 MHz Impedance 50 Connector N Female VSWR 1 5 1 Max In Band Gain 9 dBi Polarization Vertical Length 27...

Страница 21: ...mage the radio Selecting the incorrect cable could also cause significant signal loss A rule of thumb is for every 3 dB of loss your system will lose one half the output power emitted from the radio W...

Страница 22: ...Male Plug In most cases this portion of the part number will be NMSL for Zlinx Xtreme products LLLL Length in inches ex 6 six inches leading zeros are not necessary So 400M NMSL 24 is an LMR400 cable...

Страница 23: ...C Wiring Terminals Use Copper Wire Only One Conductor Per Terminal Wire Range 30 to 12 AWG Tightening Torque 0 5 to 0 6 Nm Temperature Rating of Field Installed Conductors 105 C minimum sized for 60 C...

Страница 24: ...to a DCE port and Output signals on a DCE port are Inputs to a DTE port The signal names match each other and connect pin for pin Signal flow is in the direction of the arrows The Radio Modem is a DC...

Страница 25: ...Document Number pnZXTxRM 0712m Page 24 Figure 4 3 RS 232 Wiring 4 1 4 RS 485 Two Wire Connections Figure 4 4 RS 232 Wiring...

Страница 26: ...on the PCB behind the cover Termination is switchable using DIP Switch Position 3 To enable the termination set switch 3 to ON Termination IN To disable the termination set switch 3 to OFF Termination...

Отзывы: