16
User Manual
IT8000 3/8” TIE
-LOK DATA TOOL
IT7000 1/4” TIE
-LOK DATA TOOL
ITC800 CONTROL SYSTEM
Document # P80080 Rev. C.3
© Copyright
BAND-IT-IDEX, Inc. 2024
All rights reserved
All rights reserved
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
Figure 14
Figure 12
Figure 13
CONNECTING THE TOOL TO CONTROLLER
This tool requires both electricity and compressed air to operate. Provisions must be made to deliver both to the
tool in a safe manner. The tool can be plugged in a standard 120V US or 230V EU outlet.
Connect the data cable to the main tool housing.
To reduce risk of a bent connection pin
e
nsure that the key is
aligned before attempting to screw down the connection (Fig. 12).
Each electrical connector has a unique
interface, do not attempt to force a plug into a connector if the receptable does not match or the key is
misaligned.
Connect the motor cable to the motor.
Ensure the connector is fully rotated in
the direction of the “open”
arrow, align the two triangles on the cable and motor, push cable onto motor then rotate connector by hand
in the direction of the “close” arrow
a minimum of 45
o
or until the end stop (fig. 13). Failure to follow the
order outlined above may result in bent or broken pins on the motor connector.
The tool includes an air harness with six ¼” (6.35mm) outside diameter tubes pre
-assembled to quick-connect
ends. Attach one end to the controller and the other end to the tool connection point, taking care to align keys
before insertion. Once inserted, twist coupling until it is tight on the connector.
Only plug in the power cable to the controller after all the other connections have been completed. The power
entry module includes the ON/OFF switch. The power cable provided with the tool is standard grounded plug
compatible with North America outlets.
Data Cable
Air Harness
Motor Cable
Data Cable Key
Cable Triangle
Motor Triangle