ARS-5
QUICK START GUIDE
1. Ground Input
2. Power Input
3. Ignition Input
4. Field Output
5. Bat. Temp.(+)
6. Bat. Temp.(-)
7. Stator In
8. Tach. Out
9. Alt. Temp. (+)
10. Alt. Temp. (-)
11. Dash Lamp
MC-ARS-5
Installation &
Operation Manual
www.balmar.net / Customer Service: +1 (360) 435-6100 x 1 / Technical S1 (360) 435-6100 x 3
SUP-0242 REVA
Positive Battery Sense
(Required for Internal Regulator Only)
Ignition
9
10
11
7
6
5
8
External Regulator
Plug
Isolated Ground Terminal
MUST be connected to system ground
Positive Output
Terminal
HOUSE BATTERY
BANK
D+
1
2
3
4
+
10A
Connector 1
Connector 2
The wire diagram above shows a typical set-up for a
6-Series alternator to a ARS-5 regulator. Connector 1
is for use with the internal regulator which connects to
a Yanmar engine harness. Connector 2 is used with
the ARS-5 or MC-614 (as shown).
Alternators other than the 6-Series have similar, but
slightly different connections. If programming for
specific battery type, 12.5 volts on the battery are
necessary. Please refer to the Alternator Installation
Guide for specific connections.