The output data is normally recognized by the program as
SINT, i.e. BYTE.
C
hange
is therefore clicked on in the
Module Definition
field. The required I/O format can be
selected by clicking on the field under
Name
. The data
type should be changed to DINT.
6
Start-up and operation on a Rockwell RSLogix controller (continued)
Five magnets should be used in our example. The I/O-
Assembly
8 x Position and Time
is selected so that all
positions and time information are transmitted. Three of
the eight possible magnets are not evaluated.
6.3
Configuration of the BTL7-V50D-…
If the BTL has been added to the project, configurations
can be made in the
Controller Tags
table under <Device
name>.C. The meaning of the individual parameters is
explained in chapter 5.3
Config-Assembly
is active in the example (
Config_
assembly_parameter_recognition = 1
). Five magnets are
parameterized (
Number_of_Magnets
= 5) and the direction of
measurement is reversed (
Direction _Counting_Toggle
= 1).