160
BVS HS-Q Series
Standard Hand Held Barcode Reader
Enter/Exit Programming Mode
4
Configuration Using Barcodes
GS1 DataBar™ Expanded Set Length 1
This feature specifies one of the barcode lengths for
GS1 DataBar™ Expanded Length Control on
. Length 1 is the minimum label length if in
ing, a minimum and maximum length may be set. on page 231
Mode, or the first fixed length if in
For fixed length decoding, two different lengths may be set. on page 231
Length includes the barcode’s data characters only. The length can be set from 1 to 74 charac-
ters.
Table GS1 DataBar™ Expanded Length 1 Setting Examples
provides some examples for setting
Length 1. See
for detailed instructions on setting this feature.
GS1 DataBar™
Expanded
Length 1 Setting
Examples
STEP ACTION
EXAMPLES
1
Desired Setting
01 Character 07 Characters 52 Characters 74 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT GS1 DataBar™ EXPANDED LENGTH 1SETTING
4
Scan Two Characters
From
the barcodes in this
appendix to enter
numbers as you would
select digits/characters
from a keypad.
‘0’ and ‘1’
‘0’ and ‘7’
‘5’ and ‘2’
‘7’ AND ‘4’
5
Scan ENTER/EXIT PROGRAMMING MODE
Select GS1 DataBar™ Expanded Set Length 1
Setting
Make a mistake? Scan the CANCEL barcode
to abort and not save the entry string. You can
then start again at the beginning.
CANCEL
$CXBL1
~
DEFAULT
01 = Length 1 is 1 Character
Содержание BVS HS-Q Series
Страница 1: ...Balluff BVS HS Q Family Standard Handheld Barcode Reader Operation Manual english...
Страница 282: ...282 BVS HS Q Series Standard Hand Held Barcode Reader 9 Appendix D Keypad A B C D E F...
Страница 295: ...295 www balluff com BVS HS Q Series Standard Hand Held Barcode Reader NOTES...