www.balluff.com
15
english
Output gradient
Linear
transducer
Unit
Min. value
Null value
End value
Max. value
Error
value
Rising
BTL7-A…
V
−0.5
0
+10
+10.5
+10.5
BTL7-G…
V
−10.5
−10
+10
+10.5
+10.5
BTL7-C…
mA
0
0
20
20.4
20.4
BTL7-E…
mA
3.6
4
20
20.4
3.6
Falling
BTL7-A…
V
+10.5
+10
0
−0.5
−0.5
BTL7-G...
V
+10.5
+10
−10
−10.5
−10.5
BTL7-C…
mA
20.4
20
0
0
20.4
BTL7-E…
mA
20.4
20
4
3.6
3.6
Tab. 6-1: Factory settings value table
Null point
End point
6
Installation and connection (continued)
6.3
Configuration options
Prerequisites
– USB communication box connected to the transducer
and PC.
– Software correctly installed.
– Transducer connected to the power supply.
– Magnet on transducer.
Output functions
– Position:
Position in the measuring range.
– Velocity:
velocity of the magnet. The sign indicates the
direction of movement. Movement from the null point
to the end point is output with a positive sign.
Movement from the end point to the null point is output
with a negative sign. Max. detectable velocity range of
−10 to +10 m/s.
– Velocity (no sign):
velocity of the magnet. The
direction of movement cannot be read. Max.
detectable velocity range of 0 to 10 m/s.
Freely configurable curve
– Null and end point can be read (teach-in) or specified
with the mouse.
– For position, the distance between the null point and
end point must be at least 4 mm (0.15 inch) and
100 mm/s (4 inch/s) for velocity.
– The characteristic curve can be inverted.
– The limits can be adjusted to the measuring range.
– The error value can be set in accordance with the
limits.
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
►
The system must be taken out of operation before
configuration.
►
Transducers may only be connected to the
communication box for configuration.
►
The communication box must be removed after
configuration.
BTL7-A/C/E/G50_-M_ _ _ _ -T_2/3-S32/S135/KA_ _/FA_ _