www.balluff.com
11
english
6.1
Accuracy
The specifications are typical values at 24 V DC and room
temperature, with a nominal length of 500 mm in
conjunction with the BTL5-P-3800-2, BTL5-P-4500-1,
BTL5-P-5500-2, BTL6-A-3800-2, BTL6-A-3801-2,
BTL5-F-2814-1S or BTL5-T-2814-1S magnet.
The transducer is fully operational immediately, with full
accuracy after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Resolution
< 10 µm
Repeat accuracy, typical
< 20 µm
Sampling rate
Dependent on nominal length
250 µs…4 ms
At nominal length = 500 mm
≥ 428 µs
Non-linearity at
Nominal length ≤ 500 mm
±150 µm
Nominal length > 500 mm
±0.03 % FS
Temperature coefficient
1)
≤ 20 ppm/K
6.2
Ambient conditions
2)
Operating temperature
0…+85°C
Storage temperature
−40…+100°C
Humidity
< 90%, non-condensing
Shock rating
Continuous shock
per EN 60068-2-27
3)
50 g/6 ms
50 g/2 ms
Vibration
per EN 60068-2-6
3)
12 g, 10…2000 Hz
Degree of protection per
IEC 60529 with
screwed-on connector
IP67
6.3
Supply voltage
Voltage, stabilized
4)
10…30 V DC
Ripple
≤ 2.5 V
ss
Current draw
(at 24 V DC)
≤ 80 mA
Inrush current
≤ 4 A
Reverse polarity protection
Up to 36 V
Overvoltage protection
Up to 36 V (supply cables
only!)
Dielectric strength of GND
to housing
500 V DC
6.4
Inputs/outputs
Short circuit resistance
Signal cable to GND
6.5
Dimensions, weights
Housing height
20.8 mm
Nominal length
50…4572 mm
Weight (depends on length) Approx. 1 kg/m
Housing material
Aluminum
1)
Nominal length = 500 mm, magnet in the middle of the measuring range
2)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
level.
3)
Individual specifications as per Balluff factory standard, resonant
frequencies excluded
4)
For
: The transducer must be externally connected via a limited-
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
6
Technical data
BTL6-V5 _ V-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
Содержание BTL6-V5 V-M PF-S115 Series
Страница 1: ...BTL6 V5_V M_ _ _ _ PF S115 Betriebsanleitung deutsch...
Страница 2: ...www balluff com...
Страница 17: ...BTL6 V5_V M_ _ _ _ PF S115 User s Guide english...
Страница 18: ...www balluff com...
Страница 33: ...BTL6 V5_V M_ _ _ _ PF S115 Manual de instrucciones espa ol...
Страница 34: ...www balluff com...
Страница 49: ...BTL6 V5_V M_ _ _ _ PF S115 Notice d utilisation fran ais...
Страница 50: ...www balluff com...
Страница 65: ...BTL6 V5_V M_ _ _ _ PF S115 Manuale d uso Italiano...
Страница 66: ...www balluff com...