10
english
5.1
Starting up the system
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is part
of a closed loop system whose parameters have not yet
been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
►
Persons must keep away from the system's
hazardous zones.
►
Startup must be performed only by trained technical
personnel.
►
Observe the safety instructions of the equipment or
system manufacturer.
1.
Check connections for tightness and correct polarity.
Replace damaged connections.
2.
Turn on the system.
3.
Check measured values and adjustable parameters
(especially after replacing the transducer).
5.2
Operating notes
– Check the function of the position measuring system
and all associated components on a regular basis.
– Take the position measuring system out of operation
whenever there is a malfunction.
– Secure the system against unauthorized use.
5
Startup
BTL6-V5 _ V-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
Содержание BTL6-V5 V-M PF-S115 Series
Страница 1: ...BTL6 V5_V M_ _ _ _ PF S115 Betriebsanleitung deutsch...
Страница 2: ...www balluff com...
Страница 17: ...BTL6 V5_V M_ _ _ _ PF S115 User s Guide english...
Страница 18: ...www balluff com...
Страница 33: ...BTL6 V5_V M_ _ _ _ PF S115 Manual de instrucciones espa ol...
Страница 34: ...www balluff com...
Страница 49: ...BTL6 V5_V M_ _ _ _ PF S115 Notice d utilisation fran ais...
Страница 50: ...www balluff com...
Страница 65: ...BTL6 V5_V M_ _ _ _ PF S115 Manuale d uso Italiano...
Страница 66: ...www balluff com...