6
english
Fig. 3-1: BTL6… transducer, construction
3.1
Construction
Electrical connection:
The electrical connection is made
via a connector (see Type code breakdown on page 14).
Housing:
Aluminum housing containing the waveguide
and processing electronics.
Magnet:
Defines the position to be measured on the
waveguide. Magnets are available in various models and
must be ordered separately (see Accessories starting on
Nominal length:
To optimally adapt the transducer to the
application, nominal lengths from 50 mm to 4572 mm are
available.
3.2
Function
The BTL6 transducer contains the waveguide which is
protected by an aluminum housing. A magnet is moved
along the waveguide. This magnet is connected to the
system part whose position is to be determined.
The magnet defines the position to be measured on the
waveguide.
An internally generated INIT pulse interacts with the
magnetic field of the magnet to generate a torsional wave
in the waveguide which propagates at ultrasonic speed.
The component of the torsional wave which arrives at the
end of the waveguide is absorbed in the damping zone to
prevent reflection. The component of the torsional wave
which arrives at the beginning of the waveguide is conver-
ted by a coil into an electrical signal. The travel time of the
wave is used to calculate the position.
This information is transferred via the VARAN interface.
VARAN is an industrial bus system based on the physical
layer of the Ethernet (see www.varan-bus.net).
3.3
LED display
In normal operation the LED indicates the
operating states of the VARAN bus.
LED
Operating state
Green
Ethernet Connection available
Orange
Data is being transmitted via the VARAN bus.
Tab. 3-1: LED display
3
Construction and function
63
10
63
10
13
~80
~250
~250
~80
100%
0%
1)
1)
1)
1)
-10 mm
100% +10 mm
24.8
20.8
34.8
50
68
2)
2)
Output signal rising
1) Unusable area
2) Not included in scope of delivery
Error signal
Mounting clamps with insulating bushes
and ISO 4762 M5x25 cylinder head screws,
max. tightening torque 2 Nm
BTL5-P-3800-2 magnet
Error signal
Warning
signal
Warning
signal
Null point
End point
Nominal length =
Measuring range
LED
BTL6-V5 _ V-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing
Содержание BTL6-V5 V-M PF-S115 Series
Страница 1: ...BTL6 V5_V M_ _ _ _ PF S115 Betriebsanleitung deutsch...
Страница 2: ...www balluff com...
Страница 17: ...BTL6 V5_V M_ _ _ _ PF S115 User s Guide english...
Страница 18: ...www balluff com...
Страница 33: ...BTL6 V5_V M_ _ _ _ PF S115 Manual de instrucciones espa ol...
Страница 34: ...www balluff com...
Страница 49: ...BTL6 V5_V M_ _ _ _ PF S115 Notice d utilisation fran ais...
Страница 50: ...www balluff com...
Страница 65: ...BTL6 V5_V M_ _ _ _ PF S115 Manuale d uso Italiano...
Страница 66: ...www balluff com...