The specifications are typical values for 24 V DC at room
temperature.
The sensor is fully operational immediately, with full
accuracy after warm-up.
Further data can be found at
www.balluff.com
on the product page.
9.1
General features
Light emitter
(not for …-LE10-…)
Laser (red light)
Wave length
…-LH10-…
655 nm
…-LK10/-LH11-/LS10-… 650 nm
Beam characteristic
…-LH10-…
Focus typically at 400 mm
…-LK10/-LH11-/LS10-… collimated
Laser class per
IEC 60825-1:2014
(not for …-LE10-…)
1
Average power P
o
…-LH10-…
≤ 280 μW
…-LH11-…
≤ 110 μW
≤ 35 μW (high distance
mode)
…-LK10-…
≤ 85 μW
…-LS10-…
≤ 127 μW
Pulse duration t
…-LH10-…
≤ 100 μs
…-LH11-…
≤ 3.25 μs
…-LK10/LS-…
≤ 4.6 μs
Pulse frequency
…-LH10-…
500 Hz
1000 Hz (speed mode)
…-LH11-…
4545 Hz
1270 Hz (high distance
mode)
…-LK10-…
4545 Hz
…-LS10-…
6250 Hz
Reference units
Reference reflector
(for …-LK10-…)
BOS R-22
Reference receiver
(for …-LS10-…)
BOS R254K-UUI-LE10-S4
Reference emitter
(for …-LE10-…)
BOS R254K-UUI-LS10-S4
9.2
Ambient conditions
Ambient temperature
−40…+70 °C
Storage temperature
−40…+70 °C
Protection per IEC 60529 (when
threaded together)
IP67, IP69K
Ambient light
≤ 10 kLux
9.3
Detection range/Measuring range
Range S
n
…-LH10-…
≤ 250 mm
…-LH11-…
≤ 500 mm
…-LK10-…
≤ 8 m
…-LS10/LE10-…
≤ 70 m
Range S
Adjustable
Temperature drift (% of S
n
)
≤ 10%
Light spot size
…-LH10-…
for 200 mm:
1.3 × 0.4 mm
…-LK10/LH11/LS10-…
for 500 mm:
2.5 × 2.0 mm
for 1 m:
3.0 × 2.5 mm
for 10 m:
7.0 × 6.0 mm
9
Technical data
BOS R254K-UUI-L_1_-S4
Photoelectric Sensors
Содержание BOS R254K-UUI-LE10-S4
Страница 2: ...www balluff com...
Страница 4: ...www balluff com...
Страница 20: ...www balluff com...
Страница 36: ...www balluff com...
Страница 52: ...www balluff com...
Страница 68: ...www balluff com...
Страница 83: ......