background image

27

34.

5

78.

4

18.

2

5.5

34

5

21.

2

8.

1

8.

1

3

60.2

18.5

7.5

φ

5

a

a

b

b

Fig. 1: Display- and Operating Elements 

Display- and 

operating elements

The green LED Power on/short circuit indicator

LED on: The sensor is operating  

LED flashes: Short circuit on the output

LED off: Sensor not ready

 

The yellow LED Output signal/Error indicator  

LED on: Light at the receiver 

LED flashes: Insufficient light at the receiver

LED off: No light at the receiver

10-turn potentiometer

 

without stop

 

Used for setting the switching distance. 

Photoelectric Sensors

Red light diffuse reflective with background supression BOS 50K-...-RH12-S4

No. 862 739 EN • F18

green LED: Power on Indicator/short circuit indicator

yellow LED: Output signal indicator/Error indicator 

10-turn potentiometer for precise setting of the  

switching distance

5

 

The CE Mark verifies that our products meet the 

 

requirements of the current EMC Directive.  

In our EMC Laboratory, which is accredited by the  

DATech for Testing of Electromagnetic Compatibility,  

proof has been documented that these Balluff products 

meet the EMC requirements of the harmonized standard 

EN 60947-5-2.

 Safety Notes

 

These photoelectric sensors may not be used in 

applications where personal safety depends on 

proper function of the devices  (not safety  

designed per EU machine guideline). Read these 

operating instructions carefully before putting the 

device into service.

Fig. 2: Dimensions

 Installation

Attention! Do not look into the lightbeam.

Exempt Group according to IEC 62471.

DO NOT STARE INTO THE LIGHT BEAM!

Danger of glare and irritation!

The sensor must be installed so that no direct 

looking into the light source is possible even  

during operation. 

Order Code  Diffuse reflective with background supression 

BOS0156 

BOS 50K-PSV-RH12-S4 

PNP 

N.O. 

Error output

BOS018T 

BOS 50K-NSV-RH12-S4 

NPN 

N.O. 

Error output

BOS018N 

BOS 50K-PS-RH12-S4 

PNP 

N.O. 

-

BOS018P 

BOS 50K-PA-RH12-S4 

PNP 

N.O.+ N.C. 

-

BOS018R 

BOS 50K-NA-RH12-S4 

NPN 

N.O.+ N.C. 

-

BOS018U 

BOS 50K-POV-RH12-S4 

PNP 

N.C. 

Error output

a = Optical axis of receiver

b = Optical axis of emitter

To increase the switching distance: Turn potentiometer 

clockwise.

To reduce switching distance: Turn potentiometer  

counter-clockwise. 

1. Position the sensor at the desired distance to the  

object. 

2. Set the potentiometer so that the object is reliably 

detected: The yellow LED will be on toindicate light is 

being received.  

3. Remove the object. The background should not be 

detected: The yellow LED should not be on. 

Safety Notes

Installation

Display- and Operating Elements

Setting

Содержание BOS 50K RH12-S4 Series

Страница 1: ...darf nicht erkannt werden Die gelbe LED darf nicht leuchten Achtung Blicken Sie nicht in den Lichtstrahl a Optische Achse Empf nger b Optische Achse Sender Freie Gruppe nach IEC 62471 NICHT IN DEN LI...

Страница 2: ...ite a Schaltpunkt bei 2000 mm b Schaltpunkt bei 1000 mm Bild 5 Schaltabstand Abweichung in Abh ngigkeit vom Objektabstand bei unterschiedlichen Remissionsgraden Objektabstand mm a 90 Remission wei b 1...

Страница 3: ...lschaltend Pin 4 BOS 50K POV dunkelschaltend Pin 2 Zusatzausgang nur Typ P_V N_V Fehlerausgang Empfindlichkeitseinstellung 10 Gang Poti Grauwertverschiebung bei 90 18 0 5 0 1000 mm 10 1000 2000 mm Geb...

Страница 4: ...4...

Страница 5: ...ay not be used in applications where personal safety depends on proper function of the devices not safety designed per EU machine guideline Read these operating instructions carefully before putting t...

Страница 6: ...stance at varying degrees of remission Object distance mm a 90 Remission white b 18 Remission gray c 6 Remission black Fig 6 Switching hysteresis as a function of object distance Object distance mm Hy...

Страница 7: ...de pin 4 BOS 50K POV dark on mode pin 2 Additional output P_V N_V only Error output Range setting 10 turn poti Gray value shift at 90 18 0 5 0 1000 mm 10 1000 2000 mm Utilisation category DC 13 Mechan...

Страница 8: ...Nr No 862 739 DE EN F18 nderungen vorbehalten Subject to modification Ersetzt Ausgabe Replaces edition 1106 8...

Отзывы: