Optoelektronische Sensoren
Rotlicht Lichttaster BOS 08E-PI-KH22-... mit Hintergrundausblendung und IO-Link
Servicedaten
5
System Kommandos
Index
(dez)
Daten-
format
Zugriff
Wertebereich
Bemerkungen
0x0002 (2)
System-
Command
UINT8
W
0x01 = ParamUploadStart
Blockpa-
rameteri-
zation
Start Blockparameterization Device
→
Master
0x02 = ParamUploadEnd
Stopp Blockparameterization Device
→
Master
0x03 = ParamDownloadStart
Start Blockparameterization Master
→
Device
0x04 = ParamDownloadEnd
Stopp Blockparameterization Master
→
Device
0x05 = ParamDownloadStore
Stopp Blockparameterization Master
→
Device
and Upload Request
0x06 = ParamBreak
Abort Blockparameterization
0x40 = Teach Apply
Teach
Channel
Calculate and apply SP1,2 from
Teachpoint(s)
0x41 = SP1 Single Value Teach
Determine Teachpoint 1 for SP1
0x42 = SP2 Single Value Teach
Determine Teachpoint 1 for SP2
0x43 = SP1 Two Value Teach TP1
Determine Teachpoint 1 for SP1
0x44 = SP1 Two Value Teach TP2
Determine Teachpoint 2 for SP1
0x45 = SP2 Two Value Teach TP1
Determine Teachpoint 1 for SP2
0x46 = SP2 Two Value Teach TP2
Determine Teachpoint 2 for SP2
0x47 = SP1 Dynamic Teach Start
*Start dynamic teach-in for SP1
0x48 = SP1 Dynamic Teach Stop
Stop dynamic teach-in for SP1
0x49 = SP2 Dynamic Teach Start
Start dynamic teach-in for SP2
0x4A = SP2 Dynamic Teach Stop
*Stop Dynamic teach-in for SP2
0x4F = Teach Cancel
Abort Teach-in sequence
0x4B = SP1 Fine Adjust Near
Decrement SP1
0x4C = SP1 Fine Adjust Far
Increment SP1
0x4D = SP2 Fine Adjust Near
Decrement SP2
0x4E = SP2 Fine Adjust Far
Increment SP2
0x80 = Device reset
Reset
Reset Device
0x82 = Restore factory settings
Restore factory settings
0xA0=Sensor sleep
BALLUFF
specific
Sender LED OFF
0xA1=Sensor wake-up
Sender LED ON
0xA2=Restore BDC
Restore factory settings of BDC1
* These commands shall be applied for the determination of both Setpoints SP1 and SP2 in one single teach-in procedure