background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

BNI PNT-104-105-Z015 

BNI PNT-202-105-Z015 

BNI PNT-206-105-Z015 

BNI PNT-302-105-Z015 

BNI PNT-305-105-Z015 

IP67 Modules  

User’s Guide 

 

Содержание BNI PNT-104-105-Z015

Страница 1: ...BNI PNT 104 105 Z015 BNI PNT 202 105 Z015 BNI PNT 206 105 Z015 BNI PNT 302 105 Z015 BNI PNT 305 105 Z015 IP67 Modules User s Guide...

Страница 2: ...6 Grounding 6 PROFINET Interface 6 I O Port 7 Port 7 4 Technical data 8 4 1 Dimensions 8 4 2 Mechanical data 8 4 3 Operating conditions 8 4 4 Electrical data 8 4 5 PROFINET 9 4 6 Function indicators 9...

Страница 3: ...20 6 3 AlarmSpecifier 20 Sequence Number 20 Channel Diagnostic 20 Manufacturer Specific Diagnosis 20 Submodules 20 Diagnostic State 20 ARDiagnosis State 20 User Structure ID 20 6 4 Channel Number 21 6...

Страница 4: ...1 Action result Action instruction 2 Procedures can also be shown as numbers in brackets 1 Step no 1 2 Step no 2 3 Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexade...

Страница 5: ...nauthorized tampering Improper use Use installation or handling contrary to the instructions provided in this operating manual Obligations of the Operating Company The device is a piece of equipment f...

Страница 6: ...Z015 1 Mounting hole 2 PROFINET port 2 3 Display 4 Power Supply In 5 Status LED Communication Module 6 Port 1 7 Pin Port LED Signal status 8 Port 3 9 Port 5 10 Port 7 11 Port 6 12 Port 4 13 Port 2 14...

Страница 7: ...uator power supply 0 V 2 3 Function ground FE 4 Bus Sensor power supply 24 V 5 Actuator power supply 24 V Note Provide sensor bus power and actuator power from separate power sources if possible Total...

Страница 8: ...5 Z015 Note For the digital sensor inputs follow the input guideline per EN61131 2 type 2 Note Each output serves a maximum current of 2 0 amperes Total current of the module has to be lower than 4 am...

Страница 9: ...y voltage 7 8 5 pin male and female Input ports Output ports M12 A coded 8 x female Dimensions W x H x D in mm 68 x 224 x 37 9 Mounting type 2 hole screw mount Ground strap attachment M4 Weight Approx...

Страница 10: ...dog timeout channel generic or extended diagnosis present system error red flashing DCP signal service is initiated via the bus BF off No error red No configuration or low speed physical link or no ph...

Страница 11: ...nk block are displayed in the project planning software according to the slot The GSDML file makes the possible data modules available input or output of different data ranges For configuration of the...

Страница 12: ...click on the header module to open its properties Click on the Parameter tab to open a menu selection for defining the port functions and diagnostic functions Note Standard input and output For each...

Страница 13: ...e modules allows you to change the addressing in the Addresses window Configuring a standard input output If one of the possible port pins pin 4 is to be configured with a standard function input outp...

Страница 14: ...inet www balluff com 13 5 Integration Device name Profinet address Double click on the module in the Profinet line to view the communication parameters of the module The device name and the Profinet a...

Страница 15: ...e name Assigning device name Select the desired name and use Assign name to assign the marked device that you found The device name must be the same as that previously configured under device properti...

Страница 16: ...ndervoltage optical diagnostics and diagnostics in configured diagnostics modules are not affected Actuator supply undervoltage This function can be used to permit suppress the diagnostics message Act...

Страница 17: ...e respective port pin Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Port 7 Port 6 Port 5 Port 4 Port 3 Port 2 Port 1 Port 0 Actuator warning pin 4 pin 2 Feedback if a voltage is being supplied at an...

Страница 18: ...Short circuit Sensor supply Feedback indicating the port at which there is a sensor supply short circuit Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Port 7 Port 6 Port 5 Port 4 Port 3 Port 2 Port...

Страница 19: ...ed into 3 blocks Block Header Alarm Specifier Channel Properties Byte Value Meaning Block 0 00 Block Type Block Header 1 02 2 00 Block Length 3 1E 4 01 Block Version High 5 00 Block Version Low 6 00 A...

Страница 20: ...ck Version Low 1 byte preset to 0x00 Alarm Type 2 bytes the information on the type of alarm is provided here Possible values Meaning 0x0001 Diagnostics API 4 bytes default is 0 Possible values Meanin...

Страница 21: ...y new diagnostic message Channel Diagnostic Bit 11 Possible values Meaning 0x00 No diagnosis related to channel is pending 0x01 Diagnosis related to channel is pending Manufacturer Specific Diagnosis...

Страница 22: ...t Pin 2 3 0 n Actor Short circuit Pin 4 3 0 n 6 5 Channel Properties 2 bytes subdivided as follows Type Bit 0 7 Possible values Meaning 0x00 Used if the channel number is 0x8000 or none of the types d...

Страница 23: ...as output 0x03 Channel used as input and output 6 6 Channel Error Type Error code in hex Description 0x0000 Unknown error 0x0001 Short circuit 0x0002 Undervoltage 0x0003 Overvoltage 0x0004 Overload 0x...

Страница 24: ...st ensure that the module has been correctly integrated into your network In addition the IP subnet of the BNI module must be accessible from the PC on which the browser is running Please use Internet...

Страница 25: ...the upper area of the window which allows you to switch between the various dialogs of the web interface To do this click on the corresponding icon When the Info tab is selected the following overview...

Страница 26: ...T XXX XXX XXXX BNIPNT BNI EIP XXX XXX XXXX BNIEIP BNI ECT XXX XXX XXXX BNIECT The password cannot be changed After successfully logging in the dialogs are shown as follows Use the Logout button to log...

Страница 27: ...itself and its network activity You are also shown whether the configuration block was enabled by the controller PLC Information is also shown about the current process data and the status of the modu...

Страница 28: ...Balluff Network Interface Profinet www balluff com 27 7 Webserver PNT EIP...

Страница 29: ...www balluff com 28 7 Webserver 7 5 Config dialog The configuration page enables configuration of the module You can change the module information texts and the for EIP IP Configuration PNT ECT...

Страница 30: ...e Configuration and permanently stored in the device The Reboot button reboots the device as if the power to the module had been turned off and on again Clicking on Factory Reset deletes the configura...

Страница 31: ...ich should not occur during normal operation If this happens the module must be serviced or replaced External Error Error Warning The fieldbus module has detected what may be a non permissible event w...

Страница 32: ...P MIBs Monitoring and diagnostics of the device network settings can be done over the network using the SNMPv1 protocol This can be accessed simply from a so called SNMP browser or common network mana...

Страница 33: ...s port This object may contain an octet string of zero length since IO Link is a serial P2P protocol with no specific addressing ifAdminStatus Up 1 Down 2 depending Up 1 Down 2 depending if IO Link ca...

Страница 34: ...andard Output Module 206 IP 67 Standard Output Module 302 IP 67 Standard I O Module 305 IP 67 Standard I O Module Variants 105 Display version 2 port switch Mechanical version Z015 Material Die cast z...

Страница 35: ...www balluff com 34 Notes...

Страница 36: ...www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 886160 726 E 03 124863 Edition I17 Replaces Edition 1401 Subject...