Страница 1: ...BNI PBS 504 001 K008 BNI PBS 504 002 K008 Profibus IO Link Panelmaster User s Guide...

Страница 2: ...ofibus 4 3 3 IO Link 4 3 4 Communication mode 5 Standard IO modes SIO mode 5 3 5 Replacing modules 5 4 Getting started 6 4 1 Connection overview BNI PBS 504 00x 6 4 2 Mechanical connection 7 4 3 Elect...

Страница 3: ...umbers are shown with the additional indicator hex e g 00hex Cross references Cross references indicate where additional information on the topic can be found 1 3 Symbols Attention This symbol indicat...

Страница 4: ...n and startup must only be carried out by trained technical personnel Intended use Warranty and liability claims against the manufacturer are rendered void by Unauthorized tampering Improper use Use i...

Страница 5: ...of stations as well as for data communication per IEC 61158 EN 50170 Automation devices such as PLC s PC s control and monitoring devices sensors or actuators can communicate over this bus system Vari...

Страница 6: ...time behavior Typically 2 ms cycle time 16 bits of process data and 38 4 Kbaud transmission rate Service data diagnostics parameters parallel and reactionless process data Standard IO modes SIO mode...

Страница 7: ...g started 4 1 Connection overview BNI PBS 504 00x 1 Input Output IO Link port 1 2 LED Input Output IO Link port 3 Input Output IO Link port 3 4 IO Link logo 5 Input Output IO Link port 2 6 Label 7 Sta...

Страница 8: ...e BNI PBS 504 is attached using 4 M5x10 The thread insert for mounting the module is 8mm 1 Mounting holes with 8mm thread insert 2 Ground connection 3 Power supply interface terminal plugs 4 Address s...

Страница 9: ...n 6 24V Bus communication Sensor supply 5 4 0V Bus communication Sensor supply 3 2 24 V DC max 12 A AUX AUX Power 1 0V AUX GND AUX Power Pin 1 and 2 internal bended Pin 3 and 4 internal bended Pin 1 a...

Страница 10: ...istor Unused sockets must be fitted with over caps to ensure IP54 protecting rating Pin Function 1 Protection ground 2 Not connected 3 A line 4 Not connected 5 GND Data 6 5V power for bus terminator 7...

Страница 11: ...our I O ports are provided for connecting the actuators sensors for Standard I O and or IO Link IO Link port M12 A coded female Pin Function 1 24 V DC 1 4 A 2 AUX Power 24 V 3 0 V 4 IO Link Eingang Au...

Страница 12: ...ing material Plastic Fieldbus Profibus SUB D 9 Pin female Supply power Terminal plugs spring type on the backside AUX power supply Terminal plugs spring type on the backside I O Ports M12 A coded 4 x...

Страница 13: ...K008 www balluff com 12 5 Technical Data Electrical Data Operating voltage 18 30 V DC Operation voltage AUXPower 18 30 V DC 12A Ripple 1 Current draw without load 200 mA Operating conditions Ambient...

Страница 14: ...ly connected LED 3 Green solid Green blinking BUS Data transmission active BUS Data transmission inactive I O und IO Link ports Jedem M12 Port IO Link E A Schnittstelle sind LEDs zugeordnet um die Bet...

Страница 15: ...rface Profibus Functions 504 IP 54 IO Modul 4x IO Link interfaces Pin 4 4x AUX power interfaces Variants 000 Standard version 001 Software release 001 002 IO Link specification 1 1 Mechanical version...

Страница 16: ...uff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 883191 726 DE 02 127280 Edition I18 Replaces Edition E15 Subject to modif...