Balluff Network Interface / IO-Link
www.balluff.com
30
7
Configuration: BNI IOL-302-S02-Z012-C11 extended with 22/24 valve terminal
Preface: Devices having the following configuration are covered.
All these device versions have diagnostics information in the incoming process data.
The only difference is in the max. digital output voltage
(200 mA vs. 2 A).
BNI IOL-302-S02-Z012-C11 with
- BNI IOL-751-V08-K007
- BNI IOL-751-V10-K007
- BNI IOL-751-V13-K007
Configuration
of the
extension port
Configuration
Value of IDSU-Index
55
hex
Device alone (extension port not active)
0
Device with identical device
1
Device with BNI IOL-751-V08-K007
2
Device with BNI IOL-751-V10-K007
3
Device with BNI IOL-751-V13-K007
4
IO-Link Data
BNI IOL-302-S02-Z012-C11 with 22/24 valve terminal
Transmission rate
COM2 (38.4 kBaud)
Minimum cycle time
6.8 ms
Process data length
6 bytes input / 6 bytes output