Safety 

 

Intended use 

2.1.

  The BNI IOL-

… acts as a decentralized input/output sensor module, which is connected to a 

higher-level IO-Link master module through an IO-Link interface. 

 

 

Installation and 

2.2.

Startup 

 

 

Attention! 

Installation and startup must only be carried out by trained technical personnel. 
Qualified personnel are people who are familiar with installation and operation of 
the product and have the necessary qualifications for these tasks. Any damage 
resulting from unauthorized tampering or improper use voids the manufacturer's 
guarantee and warranty. The operator must ensure that appropriate safety and 
accident prevention regulations are observed. 

 

 

 

General Safety 

2.3.

Notes 

 

Commissioning and inspection 

Before commissioning, carefully read the user's guide. 
The system must not be used in applications in which the safety of persons is dependent 
upon proper functioning of the device. 

Authorized personnel 

Installation and startup must only be carried out by trained technical personnel. 

Intended use 

Warranty and liability claims against the manufacturer are rendered void by: 

 

Unauthorized tampering 

 

Improper use 

 

Use, installation or handling contrary to the instructions provided in this user's 
guide 

Obligations of the operating company 

The device is a piece of equipment in accordance with EMC Class A. This device can 
produce RF noise. The operator must take appropriate precautionary measures. The device 
may only be used with an approved power supply. Use only approved cables. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 
taken out of operation and protected against unauthorized use. 
Intended use is ensured only when the housing is fully installed. 

 

 

Resistance to 

2.4.

Aggressive 
Substances 

 

 

Attention! 

The BNI modules always have good chemical and oil resistance. When used in 
aggressive media (such as chemicals, oils, lubricants and coolants, each in a 
high concentration (i.e. too little water content)), the material must first be 
checked for resistance in the particular application. No defect claims may be 
asserted in the event of a failure or damage to the BNI modules caused by such 
aggressive  media. 

 

 

 

Dangerous 
Voltage 

 

 

Attention! 

Before maintenance, disconnect the device from the power supply. 

 

 

 

 

 

Note 

In the interests of product improvement, Balluff GmbH reserves the right to 
change the technical data of the product and the content of this manual 
at any time without notice. 

 

 
 

Содержание BNI IOL-302-002-Z046

Страница 1: ...BNI IOL 302 002 Z046 IO Link 1 1 sensor actuator hub with extension port User s Guide...

Страница 2: ...iguration of the extension port 55hex 9 Setting the serial number 54hex 9 5 Configuration Extension Off 10 IO Link data 10 5 1 Process Data Input Data 10 5 2 Process Data Output Data 10 5 3 Parameter...

Страница 3: ...tting to Factory Settings 23 9 Technical Data 24 Dimensions 24 9 1 Mechanical Data 24 9 2 Electrical Data 24 9 3 Operating conditions 24 9 4 10 Function indicators 25 Function indicators 25 10 1 LED i...

Страница 4: ...Action instruction 1 Action result Action instruction 2 Syntax Numbers Decimal numerals are shown without an additional indicator e g 123 Hexadecimal numerals are shown with the additional indicator h...

Страница 5: ...proper use Use installation or handling contrary to the instructions provided in this user s guide Obligations of the operating company The device is a piece of equipment in accordance with EMC Class...

Страница 6: ...1 Ground connection 2 Mounting hole 3 Status LED communication 4 Part label 5 Port 1 6 Port 3 7 Port 5 8 Port 7 9 Port 9 10 Port 11 11 Port 13 12 Port 15 extension port 13 Pin Port LED signal status...

Страница 7: ...Link master module Function ground The modules are equipped with a ground connection Ground connection BNI IOL Note The function ground connection from the housing to the machine must have low impeda...

Страница 8: ...ital port BNI IOL 302 002 Z046 IN OUT Sensor actuator interface Standard in output M8 Pin Function IN OUT 1 24V 4 Input Output 3 0V Note For the digital inputs the input guideline specified in EN 6113...

Страница 9: ...IOL 302 002 Z046 0 BNI IOL 302 002 Z046 with BNI IOL 104 002 Z046 1 Note The Factory reset command does not affect the configuration of the extension port in any way Note The process data length depe...

Страница 10: ...3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 15 Pin 4 Input Port 14 Pin 4 Input Port 13 Pin 4 Input Port 12 Pin 4 Input Port 11 Pin 4 Input Port 10 Pin 4 Input Port 9 Pi...

Страница 11: ...15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex DPP ISDU Parameter Data width Access rights Default Value Index I...

Страница 12: ...9 Description Direction Port 7 Pin 4 Direction Port 6 Pin 4 Direction Port 5 Pin 4 Direction Port 4 Pin 4 Direction Port 3 Pin 4 Direction Port 2 Pin 4 Direction Port 1 Pin 4 Direction Port 0 Pin 4 D...

Страница 13: ...Description Safe state Port 11 Pin 4 Safe state Port 10 Pin 4 Safe state Port 9 Pin 4 Safe state Port 8 Pin 4 Safe state Port 15 Pin 4 Safe state Port 14 Pin 4 Safe state Port 13 Pin 4 Safe state Port...

Страница 14: ...puts 45hex Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub Index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 Description Short circuit Port 7 Pin 4 Short circuit Port 6 Pin 4 Short circuit Port 5 Pin 4 Sh...

Страница 15: ...4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 14 Pin 4 Input Port 13 Pin 4 Input Port 12 Pin 4 Input Port 11 Pin 4 Input Port 10 Pin 4 Input Port 9 Pin...

Страница 16: ...0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Description Output Port 7 Pin 4 Output Port 6 Pin 4 Output Port 5 Pin 4 Output Port 4 Pin 4 Output Port 3 Pin 4 Output Port 2 Pin 4 Output Port 1 Pin 4 Output...

Страница 17: ...tor hub M8 extended with Sensor hub M8 15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex DPP ISDU Parameter Data wi...

Страница 18: ...ersion of Port 7 Pin 4 Inversion of Port 6 Pin 4 Inversion of Port 5 Pin 4 Inversion of Port 4 Pin 4 Inversion of Port 3 Pin 4 Inversion of Port 2 Pin 4 Inversion of Port 1 Pin 4 Inversion of Port 0 P...

Страница 19: ...1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub Index 4 3 2 1 8 7 6 5 Description Safe state Port 3 Pin 4 Safe state Port 2 Pin 4 Safe state Port 1 Pin 4 Safe state Port 0 Pin 4 Safe state Port 7 Pin 4 Saf...

Страница 20: ...rt circuit Port 11 Pin 1 Short circuit Port 10 Pin 1 Short circuit Port 9 Pin 1 Short circuit Port 8 Pin 1 Byte 2 Bit 7 6 5 4 3 2 1 0 Sub Index 20 19 17 Description Outputs off UA too low Undervoltage...

Страница 21: ...rcuit Port 11 Pin 4 Short circuit Port 10 Pin 4 Short circuit Port 9 Pin 4 Short circuit Port 8 Pin 4 Actuator warning 46hex Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub Index 8 7 6 5 4 3 2 1 16 1...

Страница 22: ...e Events 7 2 IO Link Revision 1 0 Event Code Description 0x5112 Low sensor voltage US 0x5114 Low actor voltage UA 0x5410 Output Stages 0x8DF0 Retry at the extension port 0x8DF1 Device lost at the exte...

Страница 23: ...ransferred to the new device This guarantees minimal downtime Validation must be switched on in order to use the data storage For information about the configuration of data storage and validation ple...

Страница 24: ...rresponding to EN 61131 2 Ripple 1 Current consumption without load extension off 90 mA Load current PIN 1 Max 200 mA temperature dependent Load current per output PIN 4 Max 300 mA temperature depende...

Страница 25: ...unction 10 1 indicators LED indicator module status LED Status Function COM US UA Green Communication error US and UA OK Green flashing Communication OK US and UA OK Red Undervoltage actuator Red flas...

Страница 26: ...ort circuit Actuator warning Actuator short circuit Extension port The table is valid if the extension port is active If the extension port is used as a standard I O then the description from Digital...

Страница 27: ...2 002 Z046 BNI00AU BNI IOL 302 002 Z046 Balluff Network Interface IO Link interface Functions 302 16 inputs outputs Variants 002 with IO Link 1 1 extension port Mechanical configuration Z046 Die cast...

Страница 28: ...www balluff com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 930932 E Edition H16 Subject to modification...

Отзывы: