background image

IO-Link Sensor-Hub 
BNI IOL-104-

… / BNI IOL-102-… 

 

  www.balluff.com 

   

   

 

1

 

Notes to the User 

1.1.

 

About this guide 

  This guide describes the Balluff IO-Link sensor hub module. Connection to the host 

interface master is made through the IO-Link protocol. 
Functionally this compact, cost-effective module is comparable with a passive splitter box: It 
takes conventional sensor signals and passes them over the IO-Link interface. 

 

1.2.

 

Structure 

  In this guide the sections build on one another. 

Chapter 2 : Basic safety information. 
……. 

 

1.3.

 

Typographical 
conventions 

 

The following typographical conventions are used in this Guide. 

 

Enumerations 

  Enumerations are shown in list form with bullet points. 

 

Entry 1, 

 

Entry 2. 

 

Actions 

  Action instructions are indicated by a preceding triangle. The result of an action is indicated 

by an arrow. 

 

Action instruction 1. 

 

Action result. 

 

Action instruction 2. 

 

Syntax 

  Numbers: 

Decimal numbers are shown without additional indicators (e.g. 123), 
Hexadecimal numbers are shown with the additional indicator hex (e.g. 00

hex

).

 

 

Cross references 

  Cross-references indicate where additional information on the topic can be found. 

 

1.4.

 

Symbols 

 

Caution! 

This symbol indicates a security notice which most be observed 

 
 

 

Note, tip 

This symbol indicates general notes. 

 

1.5.

 

 Abbreviations 

  BCD 

BNI 
DPP 
EMC 
I-Port 
DI 
FE  
IOL  
LSB 
MSB  
SPDU 

Binary coded switch 
Balluff Network Interface 
Direct Parameter Page 
Electromagnetic Compatibility  
Digital Input-Port 
Digital In 
Function ground 
IO-Link 
Least Significant Bit 
Most Significant Bit 
Service Protocol Data Unit 

Содержание BNI IOL-104-000-K006

Страница 1: ...BNI IOL 104 000 K006 BNI IOL 102 000 K006 IO Link Sensorhub digital User s Guide ...

Страница 2: ...Getting Started 4 3 1 Connection overview 4 3 2 Mechanical connection 6 3 3 Electrical connection 6 3 4 IO Link interface 6 3 5 Sensor interface 6 4 IO Link Interface 7 4 1 Communication parameters 7 4 2 Process data 7 Input data 7 Output data 7 4 3 Parameter data On request data 7 Inversion 40hex 8 4 4 Errors 8 4 5 Events 8 5 Technical Data 9 5 1 Dimensions 9 5 2 Mechanical data 9 5 3 Electrical ...

Страница 3: ... points Entry 1 Entry 2 Actions Action instructions are indicated by a preceding triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the additional indicator hex e g 00hex Cross references Cross references indicate where add...

Страница 4: ...e installation or handling contrary to the instructions provided in this user s guide Obligations of the operating company The device is a piece of equipment in accordance with EMC Class A This device can produce RF noise The operator must take appropriate precautionary measures The device may only be used with an approved power supply Use only approved cables Malfunctions In the event of defects ...

Страница 5: ...unting hole 2 IO Link interface 3 Status LED Input Pin 2 4 Standard Input Port 1 5 Status LED Input Pin 4 6 Standard Input Port 3 7 Standard Input Port 5 8 Standard Input Port 7 9 Status LED Power Supply 10 Standard Input Port 6 11 Standard Input Port 4 12 Standard Input Port 2 13 Standard Input Port 0 14 Label 15 Status LED COM ...

Страница 6: ... interface 3 Standard Input Port 1 4 Status LED Input Pin 4 5 Standard Input Port 3 6 Standard Input Port 5 7 Standard Input Port 7 8 Status LED Power Supply 9 Standard Input Port 6 10 Standard Input Port 4 11 Standard Input Port 2 12 Standard Input Port 0 13 Label 14 Status LED COM ...

Страница 7: ...V max 1 6 A 2 3 GND reference potential 4 C Q IO Link data transmission channel Connect protection ground to FE terminal if present Connect the incoming IO Link line to the Sensor Hub Note A standard sensor cable is used for connecting to the host IO Link Master 3 5 Sensor interface Module specific connection possibilities Sensor Hub Digital Input Ports BNI IOL 104 000 K006 16 BNI IOL 102 000 K006...

Страница 8: ... Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin 2 Input Port 0 Pin 2 Only for BNI IOL 104 000 K006 Output data There is no output data at BNI IOL 102 and BNI IOL 104 4 3 Parameter data On request data DPP SPDU Parameter Data width Value range Default Value Index Index Sub index Identification Data 07hex Vendor ID 2 Byte Read only 0378hex 08hex 09hex Device ID 3 Byte 050101hex BNI IOL 104 0...

Страница 9: ...ion Port 3 Pin 4 Inversion Port 2 Pin 4 Inversion Port 1 Pin 4 Inversion Port 0 Pin 4 Inversion Port 7 Pin 2 Inversion Port 6 Pin 2 Inversion Port 5 Pin 2 Inversion Port 4 Pin 2 Inversion Port 3 Pin 2 Inversion Port 2 Pin 2 Inversion Port 1 Pin 2 Inversion Port 0 Pin 2 Only for BNI IOL 104 000 K006 4 4 Errors Error Code Description 0x8011 Index not available 0x8012 Subindex not available 0x8030 Va...

Страница 10: ...67 only when plugged in and threaded in Weight 90 g Dimensions L W H excluding connector 115 50 30 8 mm 5 3 Electrical data Operating voltage 18 30 2 V DC per EN 61131 2 Ripple 1 Current draw without load 40 mA 5 4 Operating conditions Operating temperature 5 C 55 C Storage temperature 25 C 70 C EMC Immunity tests Emission tests EN 61000 6 2 2005 AC 2005 EN 61000 6 4 2007 A1 2011 Vibration shock E...

Страница 11: ...mmunikation OK Red Communication line overload Off Module unpowered LED 3 Module supply Signal Function Green Supply voltage OK Green rapidly flashing Supply voltage 18 V Green slowly flashing Short circuit on input port Off Module unpowered Digital Inputs LEDs are associated with the digital ports which indicate the operating states LED 1 Input pin 2 only BNI IOL 104 LED 2 Input pin 4 Signal Func...

Страница 12: ...BNI0006 BNI IOL 102 000 K006 BNI0005 BNI IOL 10x 000 K006 Balluff Network Interface IO Link interface Functions 104 16 Inputs 0 1A 102 8 Inputs 0 1A Version 000 Standard version Mechanical configuration K006 Plastic housing Connectors BUS and Power Supply 1x M12x1 external thread Input Ports 8x M12x1 internal thread ...

Страница 13: ...IO Link Sensor Hub BNI IOL 104 BNI IOL 102 www balluff com 12 Notes ...

Страница 14: ...uff com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 894235 E Edition B16 Replaces Edition 1301 Subject to modification ...

Отзывы: