2  Safety 

2.1.  Intended use 

  This guide describes the Balluff IO-Link sensor collector module, also called Sensor Hub. 

Connection to the host interface master is made through the IO-Link protocol. Functionally 

this compact, cost-effective module is comparable with a passive splitter box: It takes 

conventional sensor signals and passes them over the IO-Link interface. 

 

2.2.  Installation and 

startup 

 

 

Attention! 

Installation and startup are to be performed only by trained specialists. Qualified 

personnel are persons who are familiar with the installation and operation of the 

product, and who fulfills the qualifications required for this activity. Any damage 

resulting from unauthorized manipulation or improper use voids the 

manufacturer's guarantee and warranty. The Operator is responsible for 

ensuring that applicable of safety and accident prevention regulations are 

complied with. 

 

 

 

 

2.3.  General safety 

notes 

 

Commissioning and inspection 

Before commissioning, carefully read the operating manual. 

The system must not be used in applications in which the safety of persons is dependent on 

the function of the device. 

Authorized Personnel 

Installation and commissioning may only be performed by trained specialist personnel. 

Intended use 

Warranty and liability claims against the manufacturer are rendered void by: 

• 

Unauthorized tampering 

• 

Improper use 

• 

Use, installation or handling contrary to the instructions provided in this operating 

manual 

Obligations of the Operating Company 

The device is a piece of equipment from EMC Class A. Such equipment may generate RF 

noise. The operator must take appropriate precautionary measures. The device may only be 

used with an approved power supply. Only approved cables may be used. 

Malfunctions 

In the event of defects and device malfunctions that cannot be rectified, the device must be 

taken out of operation and protected against unauthorized use. 

Intended use is ensured only when the housing is fully installed. 

 

2.4.  Resistance to 

aggressive 

substances 

 

 

Attention! 

The BNI modules generally have a good chemical and oil resistance. When 

used in aggressive media (eg chemicals, oils, lubricants and coolants each in 

high concentration (ie, low water content)) must be checked prior application-

related material compatibility. In the event of failure or damage to the BNI 

modules due to such aggressive media are no claims for defects. 

 

 

 

 

Hazardous 

voltage 

 

 

Attention! 

Disconnect all power before servicing equipment. 

 

 

 

 

 

 

Note 

In the interest of product improvement, the Balluff GmbH reserves the right to 

change the specifications of the product and the contents of this manual at any 

time without notice. 

 

 

 

 

 

Содержание BNI IOL-101-000-K018

Страница 1: ...BNI IOL 101 000 K018 BNI IOL 102 000 K019 BNI IOL 101 S01 K018 BNI IOL 102 S01 K019 User s Guide...

Страница 2: ...connection 6 3 5 IO Link Interface 6 Connecting the sensor hub 6 Module versions 6 Sensorinterface 6 4 IO Link interface 7 4 1 IO Link data 7 4 2 Process data Output data 7 4 3 Process data Input data...

Страница 3: ...on the topic can be found 1 3 Symbols Note This symbol indicates general notes Attention This symbol indicates a security notice which most be observed 1 4 Abbreviations BNI Balluff Network Interface...

Страница 4: ...ialist personnel Intended use Warranty and liability claims against the manufacturer are rendered void by Unauthorized tampering Improper use Use installation or handling contrary to the instructions...

Страница 5: ...IO Link interface 2 Mounting hole 3 Status LED Communication module 4 Standard input port 1 5 Standard input port 3 6 Standard input port 5 7 Standard input port 7 8 Mounting hole 9 Port LED Standard...

Страница 6: ...IOL 102 000 K020 BNI IOL 102 S01 K020 1 IO Link interface 2 Mounting hole 3 Status LED Communication module 4 Standard input port 1 5 Standard input port 3 6 Mounting hole 7 Port LED Standard input po...

Страница 7: ...Connecting the sensor hub Connection protection ground to FE terminal if present Connect the incoming IO Link line to the sensor hub Note A standard 3 wire sensor cable is used for connection to the h...

Страница 8: ...al cycle time 2 5 ms Process data cycle time 2 5 ms at minimal cycle time Process data length 1 Byte BNI IOL 101 S01 K018 BNI IOL 102 S01 K019 Data transmission rate COM2 38 4 kBaud Frame type 2 2 Min...

Страница 9: ...e 0 Bit 7 6 5 4 3 2 1 0 Description Input port 3 pin 4 Input port 2 pin 4 Input port 1 pin 4 Input port 0 pin 4 BNI IOL 102 000 K019 8 binary inputs Byte 0 Bit 7 6 5 4 3 2 1 0 Description Input port 7...

Страница 10: ...in 4 Error port 1 pin 4 Error port 0 pin 4 BNI IOL 102 S01 K019 8 binary inputs with single channel monitoring Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Description Input port 7 pin 4 Input port 6...

Страница 11: ...S01 K019 13hex 19 0 Product ID 7 Byte BNI000P BNI001W BNI000R BNI001Y 14hex 20 0 Product text 22 Byte Sensor Hub digital M8 4 inputs Sensor hub digital M8 4 inputs SPC Sensor hub digital M8 8 inputs S...

Страница 12: ...e Type Instance Appears Error AL Device Hardware Supply Supply low voltage U2 Supply 24V 0xC0 0x30 0x03 0x5000 0x0100 0x0010 0x0002 0xF3 0x5112 Disappears Error AL Device Hardware Supply Supply low vo...

Страница 13: ...29 IP 67 only when plugged and threaded in Dimensions W x H x D in mm BNI IOL 101 000 K018 BNI IOL 101 S01 K018 30 x 85 x 24 BNI IOL 102 000 K019 BNI IOL 102 S01 K019 30 x 129 x 24 Weight BNI IOL 101...

Страница 14: ...gure 5 3 LED indicators Module status LED 2 Communication module supply LED Indication Function LED 2 Green No communication supply ok Green negative pulsed Communication ok supply ok Red flashing Com...

Страница 15: ...LED 1 I Port Pin 4 Indication Function Yellow static Input signal 1 Off Input signal 0 LED I ports with single channel monitoring BNI IOL 101 S01 K018 BNI IOL 102 S01 K019 LED 1 I Port Pin 4 with sing...

Страница 16: ...face and power supply 1xM12 external thread I ports 4xM8 female 3 pole K019 Plastic housing M8 8 port IO Link interface and power supply 1xM12 external thread I ports 8xM8 female 3 pole 6 2 Order info...

Страница 17: ...Balluff Network Interface IO Link www balluff com 16 Notes...

Страница 18: ...ww balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Deutschland Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 919510 726 E 01 128382 Edition E19 Replaces Edition L14 Subjec...

Отзывы: