4  IO-Link interface 

4.4.  Parameter data/ 

Request data 

 

 

DPP 

SPDU 

Object name  Length  Range 

Default value 

Index 

Index  Sub-

index 

Id

en

tif

icat

io

n D

at

07

hex 

07

 

 

 

Vendor ID 

2 Byte 

R

ead onl

0378

hex

 

08

hex 

08

 

 

 

09

hex 

09

 

 

 

Device ID 

3 Byte 

0x050108 

0x05010A 

0x050104 

0x050106 

0A

hex 

10

 

 

 

0B

hex 

11

 

 

 

 

10

hex 

16

 

Vendor name 

7 Byte 

BALLUFF 

11

hex 

17

 

Vendor text 

15 Byte 

www.balluff.com 

12

hex 

18

 

Product 

name 

20 Byte 

BNI IOL-101-000-K018 

BNI IOL-101-S01-K018 

BNI IOL-102-000-K019 

BNI IOL-102-S01-K019

 

13

hex 

19

 

Product ID 

7 Byte 

BNI000P 

BNI001W 

BNI000R 

BNI001Y 

14

hex 

20

 

Product text 

22 Byte 

Sensor-Hub digital M8 

4 inputs 

Sensor hub digital M8 

4 inputs SPC 

Sensor hub digital M8 

8 inputs 

Sensor hub digital M8 

8 inputs SPC 

16

hex 

22

 

Hardware 

Revision 

1 Byte 

17

hex 

23

 

Firmware 

Revision 

23 Byte 

 

 

 

 

 

DPP 

SPDU 

Object name 

Length 

Range 

Default 

value 

Index  Index 

Sub-

index 

Par

am

et

er

 D

at

 

40

hex

 

64 

1-8 

Inversion 

1 Byte 

0-FF 

0

hex

 

 

 

 

 

 

 

 

 

 

Inversion of the 

inputs 40

hex

 

 

 

 

Byte 

Bit 

D

escr

ip

tio

Inv

er

si

on 

por

t 7

 pi

n 4

Inv

er

si

on 

por

t 6 

pi

n 4

Inv

er

si

on 

por

t 5

 pi

n 4

Inv

er

si

on 

por

t 4

 pi

n 4

Inv

er

si

on 

por

t 3 pi

Inv

er

si

on 

por

t 2 pi

Inv

er

si

on 

por

t 1 pi

Inv

er

si

on 

por

t 0 pi

 

*not used at BNI IOL-101-000-K018 

 

Содержание BNI IOL-101-000-K018

Страница 1: ...BNI IOL 101 000 K018 BNI IOL 102 000 K019 BNI IOL 101 S01 K018 BNI IOL 102 S01 K019 User s Guide...

Страница 2: ...connection 6 3 5 IO Link Interface 6 Connecting the sensor hub 6 Module versions 6 Sensorinterface 6 4 IO Link interface 7 4 1 IO Link data 7 4 2 Process data Output data 7 4 3 Process data Input data...

Страница 3: ...on the topic can be found 1 3 Symbols Note This symbol indicates general notes Attention This symbol indicates a security notice which most be observed 1 4 Abbreviations BNI Balluff Network Interface...

Страница 4: ...ialist personnel Intended use Warranty and liability claims against the manufacturer are rendered void by Unauthorized tampering Improper use Use installation or handling contrary to the instructions...

Страница 5: ...IO Link interface 2 Mounting hole 3 Status LED Communication module 4 Standard input port 1 5 Standard input port 3 6 Standard input port 5 7 Standard input port 7 8 Mounting hole 9 Port LED Standard...

Страница 6: ...IOL 102 000 K020 BNI IOL 102 S01 K020 1 IO Link interface 2 Mounting hole 3 Status LED Communication module 4 Standard input port 1 5 Standard input port 3 6 Mounting hole 7 Port LED Standard input po...

Страница 7: ...Connecting the sensor hub Connection protection ground to FE terminal if present Connect the incoming IO Link line to the sensor hub Note A standard 3 wire sensor cable is used for connection to the h...

Страница 8: ...al cycle time 2 5 ms Process data cycle time 2 5 ms at minimal cycle time Process data length 1 Byte BNI IOL 101 S01 K018 BNI IOL 102 S01 K019 Data transmission rate COM2 38 4 kBaud Frame type 2 2 Min...

Страница 9: ...e 0 Bit 7 6 5 4 3 2 1 0 Description Input port 3 pin 4 Input port 2 pin 4 Input port 1 pin 4 Input port 0 pin 4 BNI IOL 102 000 K019 8 binary inputs Byte 0 Bit 7 6 5 4 3 2 1 0 Description Input port 7...

Страница 10: ...in 4 Error port 1 pin 4 Error port 0 pin 4 BNI IOL 102 S01 K019 8 binary inputs with single channel monitoring Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Description Input port 7 pin 4 Input port 6...

Страница 11: ...S01 K019 13hex 19 0 Product ID 7 Byte BNI000P BNI001W BNI000R BNI001Y 14hex 20 0 Product text 22 Byte Sensor Hub digital M8 4 inputs Sensor hub digital M8 4 inputs SPC Sensor hub digital M8 8 inputs S...

Страница 12: ...e Type Instance Appears Error AL Device Hardware Supply Supply low voltage U2 Supply 24V 0xC0 0x30 0x03 0x5000 0x0100 0x0010 0x0002 0xF3 0x5112 Disappears Error AL Device Hardware Supply Supply low vo...

Страница 13: ...29 IP 67 only when plugged and threaded in Dimensions W x H x D in mm BNI IOL 101 000 K018 BNI IOL 101 S01 K018 30 x 85 x 24 BNI IOL 102 000 K019 BNI IOL 102 S01 K019 30 x 129 x 24 Weight BNI IOL 101...

Страница 14: ...gure 5 3 LED indicators Module status LED 2 Communication module supply LED Indication Function LED 2 Green No communication supply ok Green negative pulsed Communication ok supply ok Red flashing Com...

Страница 15: ...LED 1 I Port Pin 4 Indication Function Yellow static Input signal 1 Off Input signal 0 LED I ports with single channel monitoring BNI IOL 101 S01 K018 BNI IOL 102 S01 K019 LED 1 I Port Pin 4 with sing...

Страница 16: ...face and power supply 1xM12 external thread I ports 4xM8 female 3 pole K019 Plastic housing M8 8 port IO Link interface and power supply 1xM12 external thread I ports 8xM8 female 3 pole 6 2 Order info...

Страница 17: ...Balluff Network Interface IO Link www balluff com 16 Notes...

Страница 18: ...ww balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Deutschland Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 919510 726 E 01 128382 Edition E19 Replaces Edition L14 Subjec...

Отзывы: