background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  

 

BNI EIP-306-000-Z010 

BNI EIP-306-100-Z010 

IP67 Module,16 Inputs and 16 Outputs 

BNI EIP-308-100-Z010 

IP67 Module, 32 In-/Outputs 

User’s Guide 

 

Содержание BNI EIP-306-100-Z010

Страница 1: ...BNI EIP 306 000 Z010 BNI EIP 306 100 Z010 IP67 Module 16 Inputs and 16 Outputs BNI EIP 308 100 Z010 IP67 Module 32 In Outputs User s Guide...

Страница 2: ...ding 8 Ethernet IP Interface 8 I O Port 9 4 Technical data 10 4 1 Dimensions 10 4 2 Mechanical data 10 4 3 Operating conditions 10 4 4 Electrical data 10 4 5 Ethernet 11 4 6 Function indicators 11 Por...

Страница 3: ...Balluff Network Interface EtherNet IP BNI EIP 302 105 Z015 www balluff com 2 8 4 Diagnostic Module 19 8 5 Configurations 19 9 Appendix 20 9 1 Product Name 20 9 2 Order Code 20 9 3 Included Material 20...

Страница 4: ...g triangle The result of an action is indicated by an arrow Action instruction 1 Action result Action instruction 2 Procedures can also be shown as numbers in brackets Step no 1 Step no 2 Syntax Numbe...

Страница 5: ...autionary measures accordingly The device must be powered only using an approved power supply see chapter 4 Technical data Only approved cable may be used Operating and testing The operator is respons...

Страница 6: ...tput 7 Port 12 13 Output 8 Port 14 15 Output 9 Port 08 09 Input 10 Port 10 11 Input 11 Port 12 13 Input 12 Port 14 15 Input 13 Port 06 07 Input 14 Port 04 05 Input 15 Port 02 03 Input 16 Port 00 01 In...

Страница 7: ...Signal status 7 Port 10 11 Output 8 Port 12 13 Output 9 Port 14 15 Output 10 Port 08 09 Input 11 Port 10 11 Input 12 Port 12 13 Input 13 Port 14 15 Input 14 Port 06 07 Input 15 Port 04 05 Input 16 Po...

Страница 8: ...In Output 9 Port 24 25 In Output 10 Port 26 27 In Output 11 Port 28 29 In Output 12 Port 30 31 In Output 13 Port 22 23 In Output 14 Port 20 21 In Output 15 Port 18 19 In Output 16 Port 16 17 In Outpu...

Страница 9: ...24 V Input Power 3 0 V Input Power Common GND 4 0 V Output Power Common GND Note tip Provide sensor bus power and actuator power from separate power sources if possible Total current 9A The total cur...

Страница 10: ...Output 3 0V 0V 0V 4 Input 2 Output 2 In Output 5 FE FE FE Note For the digital sensor inputs follow the input guideline per EN61131 2 type 2 Note Each output serves a maximum current of 2 amperes Tota...

Страница 11: ...ports M12 A coded 8 x female Dimensions W x H x D in mm 68 x 334 x 32 4 Mounting type 2 hole screw mount Ground strap attachment M4 Weight Approx 900 g 4 3 Operating conditions Operating temperature...

Страница 12: ...Net off Module got no IP address green flashing Module got IP but no connection could be established green Connection established red flashing Connection timeout red green flashing Initial sequence 10...

Страница 13: ...erNet IP www balluff com 12 5 Integration 5 1 Integration into RSLogix 3 Start Open RSLogix 5000 Project 4 Add EtherNet IP Communication Module to the I O Configuration 5 Right Click I O Configuration...

Страница 14: ...ck OK Configuration of the generic module for Balluff EtherNet IP modules 8 Name of the module 9 Choose Data SINT at Comm Format 10 Enter the IP address for the Balluff module 11 Entert the Assembly I...

Страница 15: ...HS12 HS11 HS10 HS9 HS8 6 OL23 OL22 OL21 OL20 OL19 OL18 OL17 OL16 Overload status 7 OL31 OL30 OL29 OL28 OL27 OL26 OL25 OL24 8 PS PA Power status PS Sensor Power PA Actor power 6 2 Process Data Output B...

Страница 16: ...10 O112 O114 O102 O104 O92 O94 O82 O84 11 O152 O154 O142 O144 O132 O134 O122 O124 12 0 0 0 0 0 0 PS PA Power status PS Sensor power PA Actor power 6 4 Process Data Outputs BNI EIP 308 Byte Bit Descri...

Страница 17: ...for the display which can be activated out of the control system If the lock is set editing isn t possible anymore see Bit layout chapter 8 Appendix Address Defaults IP Address 169 254 1 1 Subnetmask...

Страница 18: ...ctet of the selected address type by short keypress on arrow key 7 4 Octet scrolling Octet scrolling is similar for all Address types actual state change over S condition short time keypress on set ke...

Страница 19: ...nfiguration the module is working with are shown by a unequal symbol In editing mode the screen flashes If the module receives a single ping the word ping is shown in the display screen for a few seco...

Страница 20: ...u can get some information about the configuration and network activity of the module At the top of the window you can see the navigation bar which allows you to switch between the different web pages...

Страница 21: ...llowing components I O block 4 blind plugs M12 Ground strap Screw M4x6 20 labels BNI EIP 308 100 Z010 Balluff Network Interface Ethernet IP Functions 306 IP67 I O Module 16 Inputs and 16 Outputs 308 I...

Страница 22: ...ff com www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de Nr 887581 E Edition 1203 Revised Edition 1201 Subject to modi...

Отзывы: