28
7.5
Dati parametrici
Indice
Subindice
Parametro
Dimen-
sioni
Accesso Archiviazione
dati
MDC (Measurement Data Channel)
(vedere capitolo 7.5.1)
0x00C1 (193)
0
Offset
4 byte
Read/Write
X
0x00C2 (194)
0
Preset
4 byte
Read/Write
X
0x00C3 (195)
0
Output Characteristics
1 byte
Read/Write
X
0x00C4 (196)
0
Enable Detection Range
1 byte
Read Only
0x4080 (16512) 0, 1, 2, 3, 4
MDC Describer
11 byte
Read Only
0x0202 (514)
0, 1, 2
Physical Measurement Limits
8 byte
Read/Write
X
SSC (Switching Signal Channels)
(vedere capitolo 7.5.2)
0x003A (58)
0
Teach-In Select
1 byte
Read/Write
0x003B (59)
0
Teach-In Result
1 byte
Read Only
0x003C (60)
0, 1, 2
SSC1 Parameter
8 byte
Read/Write
X
0x003D (61)
0, 1, 2, 3
SSC1 Configurartion
4 byte
Read/Write
X
0x003E (62)
0, 1, 2
SSC2 Parameter
8 byte
Read/Write
X
0x003F (63)
0, 1, 2, 3
SSC2 Configurartion
4 byte
Read/Write
X
0x4000 (16384) 0, 1, 2
SSC3 Parameter
8 byte
Read/Write
X
0x4001 (16385) 0, 1, 2, 3
SSC3 Configurartion
4 byte
Read/Write
X
0x4002 (16386) 0, 1, 2
SSC4 Parameter
8 byte
Read/Write
X
0x4003 (16387) 0, 1, 2, 3
SSC4 Configurartion
4 byte
Read/Write
X
Device Configuration
0x00B4 (180)
0, 1, 2
Output Type (vedere capitolo 7.5.4)
2 byte
Read/Write
X
0x00F8 (248)
0, 1, 2
Diagnosis Suppression Configuration
(vedere capitolo 7.5.5)
2 byte
Read/Write
X
Condition Monitoring
0x00CE (206)
1)
0
Low Signal Quality Threshold
(vedere capitolo 7.5.11)
10 byte
Read/Write
X
0x00CF (207)
1)
0, 1, 2, 3, 4, 5
Signal Quality (vedere capitolo 7.5.10)
4 byte
Read Only
0x0052 (82)
0, 1, 2, 3, 4, 5
Device Temperature (vedere capitolo 7.5.6)
5 byte
Read Only
0x0053 (83)
0, 1, 2
Temperature Thresholds
(vedere capitolo 7.5.7)
2 byte
Read/Write
X
0x0057 (87)
0, 1, 2, 3
Operating Hours (vedere capitolo 7.5.8)
12 byte
Read Only
0x0058 (88)
0
Boot Cycle counter (vedere capitolo 7.5.9)
4 byte
Read Only
Parametri di sistema
0x0003 (3)
0, 1, 2, 3, 4, 5
Data Storage (vedere capitolo 7.5.12)
69/72
byte
Read/Write
0x000C (12)
0
Device Access Locks
(vedere capitolo 7.5.13)
2 byte
Read/Write
X
0x000D (13)
0
ProfileCharacteristic (vedere capitolo 7.5.14) 14 byte
Read Only
0x000E (14)
0
PD Input Descriptor (vedere capitolo 7.5.15)
9 byte
Read Only
1)
disponibile solo per la variante
Enhanced Profile
(BML SL1-ALZ1-U
E
ZZ-_U1L-_ _ _ _)
Tab. 7-6: Dati parametrici interfaccia IO-Link
7
IO-Link-Smart-Sensor-Profil Ed. 2 (BML SL1-ALZ1-UE/MZZ-_U1L-…) (continuazione)
BML SL1-ALZ _ -U_ ZZ- _ U1L - _ _ _ _
Encoder assoluto magnetico
italiano
Содержание BML SL1-ALZ-U-ZZ-U1L Series
Страница 2: ...www balluff com...
Страница 3: ...deutsch Betriebsanleitung BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Страница 4: ...www balluff com...
Страница 52: ......
Страница 53: ...english User s Guide BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Страница 54: ...www balluff com...
Страница 102: ......
Страница 103: ...fran ais Notice d utilisation BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Страница 104: ...www balluff com...
Страница 152: ......
Страница 153: ...italiano Manuale d uso BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Страница 154: ...www balluff com...
Страница 202: ......
Страница 203: ...espa ol Manual de instrucciones BML SL1 ALZ_ U_ZZ _U1L _ _ _ _...
Страница 204: ...www balluff com...