14
english
The device cannot distinguish whether the light
band is completely blocked or whether the laser
has failed or is not plugged in.
In addition to the PDI, there is a PDO value:
No.
variable
Length
(bit)
Type
Content
1
8
Bitmask
Bit 0 Reset counter
This value can be used to reset the sequential counter to
0. This happens when the value is changed from 0 to 1.
5.3
Parameter data
5.3.1 Identification data
Index Object
name
Length
(Byte)
Access Default value
0x07 Vendor ID
2
RO
888 (0x0378)
0x09 Device ID
3
RO
721409
(0x0B0201)
0x10 Vendor-
Name
7
RO
"BALLUFF"
0x11 Vendor-Text 15
RO
"www.balluff.com"
0x12 Product
designation
14
RO
"BLA 016C-002-
00,25-S75"
0x13 Product ID
7
RO
"BLA0007"
0x14 Product
Text
19
RO
"Balluff Light
Array"
0x15 Serial No.
8
RO
(individuelle S/N)
0x16 Hardware
Revision
4
RO
Vx.x
0x17 Firmware
Revision
5
RO
Vx.xx
0x18 Application
tag*
32
R/W
RO:
Read-only
R/W:
Read and write access
*:
The application tag can be defined by the user.
5.3.2 System Commands
Under the index 0x02 (length 1 byte), the system com-
mands for executing the corresponding functions are
available under the values listed below:
Value
Function
0x80
Restart device
0x82
Restore factory settings
0xA0
Signal normalization
0xA5
Reset maintenance interval
0xA6
Set sequential counter to 0
0xAF
Device discovery
5.1
IO-Link data
Due to its compact design, the BLA16 can only be para-
meterised and read out via IO-Link.
The characteristic parameters of the interface are:
Data transfer rate
COM2 (38,4 kBaud)
Minimum cycle time
6.8 ms
Process data length
14 Byte PDI + 1 Byte PDO
IO-Link Revision
1.1
1.0
Frame type
2.V
1.2 / 1.1
5.2
Process data
For continuous data transmission, 14 bytes of process
data (PDI) are transmitted:
No.
variable
Length
(bit)
Type
Content
1
32
IntergerT
Analog output value 2
2
32
IntergerT
Analog output value 1
3
8
UIntergerT Object output value
4
16
UIntergerT Counting output value 1
5
16
UIntergerT Counting output value 2
6
8
Bitmask
Bit 3 Counter limit 1
reached
[Counter 1 Flag]
Bit 4 Counter limit 2
reached
[Counter 2 Flag]
Bit 6 Autoblanking
active
Bit 7 Data invalid
The analog output values are in µm, the value range here
is from 0 to 16256, which corresponds to the active
measuring range of the sensor.
The object output value gives the number of the detected
object. (0: no object; 1-6: detected objects; 7: unknown
object).
If the mode objects counting or slits counting is selected,
the number of detected objects, up to a maximum of 16,
is output in the object output value.
If activated, the counter status of the corresponding
sequential counter is output in the corresponding counter
output value.
If analog output, object detection or counter are deactiva-
ted, the corresponding output values are set to 0.
Several status messages are output simultaneously in
variable no. 6:
Bit 3 or bit 4 indicates whether the counter 1 or counter 2
has reached the set limit.
Bit 6 indicates whether autoblanking was activated during
the last teach event.
If no light arrives at the receiver, bit 7 is set to 1. With this,
a completely blocked light band can be detected.
5
IO-Link interface
BLA 16C-002-00,25-S75
Balluff Light Array