56
english
6.6
LED Meaning and Configuration
6.6.1 Description
Only the signal with the highest priority is displayed. The
signals are listed in descending priority.
Balluff Standard (as-delivered state)
(BIS M-4A3-082-401-07-S4
BIS M-4A6-082-401-07-S4
BIS M-4A7-082-401-07-S4)
Name
Signal
Meaning
Device Discovery
Blue, flashing, 3 Hz
The Device Discovery can be activated via a system
command to find the device again.
Short Circuit Pin 2 / Pin 4
Red, flashing, 3 Hz
Short circuit at pin 2 or pin 4
Failure
Red, static
General error
Teach-in
Red, static
The device is currently in teach-in mode
Maintenance Required
Blue, static
Maintenance must be performed. Threshold value of
inclination is exceeded (default: Function switched off).
Bad Signal Quality
Orange, flashing, 1 Hz
Poor signal quality (number of bad data carrier accesses)
Out of Specification
Yellow, flashing, 3 Hz
The device is operated outside of specifications.
Data Carrier Access Active
Static white
Data carrier communication (read or write)
Function Display
Yellow, static
CP signal (data carrier within RFID range)
Communication
Green, alternating with
LED off in a ratio of 10:1,
1 s period
IO-Link communication is active. The device is ready.
Ready Diagnosis On
Green, static
The device is ready. Diagnosis functions are on.
Tab. 6-17: LED meaning and configuration – Balluff Standard