www.balluff.com
47
english
5.9
Storage Usage Monitoring
5.9.1 Description
All variable data is stored in a permanent memory on the
device. The data is stored in various segments for different
access and usage purposes.
Because the number of write cycles in the permanent
memory is limited, the number in each segment is
monitored by a counter.
All data segments are protected with a CRC32 checksum.
5.9.2 Events
Event Code
Event Type
Description
Device Status
0x8D22 (36130)
Warning
Warning limit for write cycles reached –
maintenance monitoring no longer guaranteed – for
information purposes only.
0 – Device is operating properly.
0x8D23 (36131)
Error
Write cycle limit reached – saving no longer
ensured – replacement recommended.
1 – Maintenance-Required
0x8D24 (36132)
Warning
Parameter write error – An error occurred while
writing the data – for information purposes only.
0 – Device is operating properly.
Tab. 5-40: Storage usage monitoring – Events
5
Secondary Device Functions (continued)
BIS M-4 _ _ -082-401-07-…
Industrial RFID-System BIS M