59
59
E
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Head 1
Head 2
S1
S2
1
2
3
4
5
6
7
8
Changing the
EEPROM in the
BIS C-6002
processor
Location of the
EEPROM
BIS C-6002
Changing the EEPROM
To replace the EEPROM, open up the processor as described on 50.
Be sure before opening that the unit is discon-
nected from power..
To avoid damaging the EEPROM, please ob-
serve the requirements for handling electrostati-
cally sensitive components.
The EEPROM is replaced by unplugging and
plugging back into the socket.
C60_2-028_823024_0401-e.p65
60
60
E
Dimensions,
Weight
Housing
Plastic ABS
Dimensions with read/write head BIS C-65_
ca. 169 x 90 x 35 mm
Dimensions with adapter BIS C-650
ca. 185 x 90 x 35 mm
Weight
approx. 500 g
Ambient temperature
0 °C to + 50 °C
Enclosure rating
IP 65 (with read/write head)
Terminal block
19-pin
Cable entry
2 x PG 11 fittings (metal)
Cable diameter
5 to 10 mm
Cable entry
1 x PG 9 fittings (metal)
Cable diameter
4 to 8 mm
Conductor size
0.14 to 1 mm
2
with ferrules
0.25 to 0.34 mm
2
Integral connector X1 for
V
S
, IN
5-pin (male)
Integral connector X2 for
PROFIBUS-DP
Input
5-pin (male)
Integral connector X3 for
PROFIBUS-DP
Output 5-pin (female)
Supply voltage V
S
, input
DC 24 V ± 20 %
Ripple
≤
10 %
Current draw
≤
400 mA
PROFIBUS-DP
slave
Terminal block, electrically isolated
Operating
Conditions
Connections
BIS C-6002-...-KL2
Enclosure Rating
Electrical
Connections
BIS C-6002
Technical Data
Connections
BIS C-6002-...-ST11
All manuals and user guides at all-guides.com