37
37
E
Read 17 bytes starting at data carrier address 10
(data carrier type with 32 byte block size)
:
Example No. 4
For configuring with
double bit header
and 8-byte buffer
size!
7.)
Process subaddresses of the input buffer:
8.)
Process subaddresses of the input buffer:
BIS C-60_2 Identification System:
2.)
Process subaddresses of the input buffer in the
order shown:
3.)
Process subaddresses of the input buffer:
4.)
Process subaddresses of the input buffer:
6.)
Process subaddresses of the input buffer:
5.)
Process subaddresses of the input buffer:
Host:
1.)
Process subaddresses of the output buffer in the
order shown:
01
Hex
Command designator 01
Hex
02
Hex
Start address Low Byte 0A
Hex
03
Hex
Start address High Byte 00
Hex
04
Hex
No. of bytes Low Byte 11
Hex
05
Hex
No. of bytes High Byte 00
Hex
00
Hex
/07
Hex
CT-Bit to 0 (32 Byte block size),
set AV-Bit
00
Hex
/07
Hex
Set AA-Bit
01...06
Hex
Enter first 6 bytes of data
00
Hex
/07
Hex
Set AE-Bit
01...06
Hex
Copy first 6 data bytes
Process subaddress of the output buffer:
00
Hex
/07
Hex
Invert TI-Bit
01...06
Hex
Enter the second 6 data bytes
00
Hex
/07
Hex
Invert TO-Bit
01...06
Hex
Copy second 6 data bytes
Process subaddress of the output buffer:
00
Hex
/07
Hex
Invert TI-Bit
01...05
Hex
Enter the remaining 5 data bytes
00
Hex
/07
Hex
Invert TO-Bit
01...05
Hex
Copy the remaining 5 data bytes
Process subaddress of the output buffer:
00
Hex
/07
Hex
Reset AV-Bit
00
Hex
/07
Hex
Reset AA-Bit and AE-Bit
Function Description
Examples for protocol sequence
C60_2-028_823024_0401-e.p65
38
38
E
Example No. 5
For configuring with
double bit header
and 8-byte buffer
size!
Read 30 bytes starting at data carrier address 10 with read error
(data carrier type with 64 byte block size)
:
Host:
1.)
Process subaddresses of the output buffer in the
order shown:
BIS C-60_2 Identification System:
2.)
Process subaddresses of the input buffer in the
order shown:
If an error occurs right away:
3.)
Process subaddress of the input buffer:
4.)
Process subaddresses of the input buffer:
01
Hex
Command designator 01
Hex
02
Hex
Start address Low Byte 0A
Hex
03
Hex
Start address High Byte 00
Hex
04
Hex
No. of bytes Low Byte 1E
Hex
05
Hex
No. of bytes High Byte 00
Hex
00
Hex
/07
Hex
Set CT-Bit to 1 (64 Byte block size),
set AV-Bit
00
Hex
/07
Hex
Set AA-Bit
01
Hex
Enter error number
00
Hex
/07
Hex
Set AF-Bit
01
Hex
Copy error number
Process subaddress of the output buffer:
00
Hex
/07
Hex
Reset AV-Bit
00
Hex
/07
Hex
Reset AA-Bit and AF-Bit
Function Description
Examples for protocol sequence