Balluff Inductive Coupler
Base BIC 1I0-IAA50-M30MI3-SM4A4A and
Remote BIC 2I0-IAA50-M30MI3-SM4A5A
Remote BIC 2I0-IAA50-M30MI3-BPX04-002-M45A
www.balluff.com
12
8 IO-Link-communication
8.2. Parameters
Various base parameters can be accessed via IO-Link. All parameters are read-only, so they
involve information, not configuration options. The "Identification data" can contain texts and
information about the base. The Direct Parameter page of the IO-Link device connected to
the remote is displayed in the "Parameter data".
DPP
SPDU
Description
Length
Default value
Index Index Sub
Index
Id
en
tif
ic
at
io
n d
at
a
0 x 07
Vendor ID
2 bytes 0 x 0378
0 x 08
0 x 09
Device ID
3 bytes 0 x 050602
0 x 0A
0 x 0B
0 x 10 0
Vendor name
7 bytes BALLUFF
0 x 11 0
Vendor text
15 bytes www.balluff.com
0 x 12 0
Product name
37 bytes BIC 1I0-IAA50-M30MI3-
SM4A4A
0 x 13 0
Product ID
7 bytes BIC0053
0 x 14 0
Product text
34 bytes BIC IOL Base extended
0 x 16 0
Hardware revision
3 bytes
0 x 17 0
Firmware revision
3 bytes
Par
amet
er
iz
at
io
n d
at
a
0 x 40
64
0
1 –
16
Direct Parameter
page of the IO-Link
device on the remote
16 bytes
8.3. Events
Event 1
Event 2
Event classification
Detailed information
Mode
Type Instance
0 x F3
0 x 5112
0 x C0
0 x 30
0 x 03
0 x 5000
0 x 0100
0 x 0010
0 x 0002
coming
Error
Application Hardware
Supply
Supply low
voltage
U2 = supply
+ 24 V
Supply voltage is too low
0 x B3
0 x 5112
0 x 80
0 x 30
0 x 03
0 x 5000
0 x 0100
0 x 0010
0 x 0002
going
Error
Application Hardware
Supply
Supply low
voltage
U2 = supply
+ 24 V
Supply voltage is OK again