background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIC IO-Link unidirectional  

500 mA, IP67, 11 bytes 

User´s Guide 

 

 

Содержание BIC 2I0-IAA50-M30MI3-SM4A5A

Страница 1: ...BIC IO Link unidirectional 500 mA IP67 11 bytes User s Guide...

Страница 2: ...is 6 4 1 Base indicators 6 4 2 Remote indicators 6 5 Installation and Connection 7 5 1 Mutual Interference 7 5 2 Installation in Metal 7 5 3 Angular offset 7 5 4 connection 8 5 5 Series connection 8 6...

Страница 3: ...Balluff Network Interface www balluff com 2 10 Type Designation Code 14 10 1 Type Code 14 10 2 Order code 14...

Страница 4: ...tions Enumerations are shown as a list with bullet points Entry 1 Entry 2 Syntax Numbers Decimal numbers are shown without additional indicators e g 123 Hexadecimal numbers are shown with the addition...

Страница 5: ...cannot be rectified the device must be taken out of operation and protected against unauthorized use 2 5 Meaning of the Warning Notices The warning notices in this guide and the measures described fo...

Страница 6: ...e energy available for the IO Link device is dependent on the distance and on the offset between base and remote and is therefore limited For this reason the total current consumption of the connected...

Страница 7: ...flashing inversely IO Link communication between master and base is OK Red flashing No remote detected Red off Remote present IO Link communication OK Red static Remote present no IO Link communicati...

Страница 8: ...tallic objects on the coil cap cause the objects to be heated Install the components so that no metallic objects can collect on the coil cap There is a fire hazard When installing in metal the specifi...

Страница 9: ...ger than 20 m 5 5 Series connection Two BIC systems can be connected in series Caution This cuts the power in half from 500 mA to 250 mA The cable length between the individual components in each case...

Страница 10: ...t Approx 160 g Tightening torque 70 Nm 6 3 Operating conditions Transmission distance 1 to 5 mm Operating temperature Ta 0 C to 55 C Storage temperature range 25 C to 75 C 6 4 Electrical data Supply v...

Страница 11: ...wed down state Connection type M12 A coded Cable PUR Dimensions D x L in mm M30 X 106 Weight Approx 160 g Tightening torque 70 Nm 7 3 Operating conditions Transmission distance 1 to 5 mm Operating tem...

Страница 12: ...g unused bytes are transmitted with 0 Bytes 0 to 9 7 6 5 4 3 2 1 0 Process data of the connected IO Link devices Byte 10 7 6 5 4 3 2 1 0 Not used Not used Not used Not used Status Supply remote Status...

Страница 13: ...x 050602 0 x 0A 0 x 0B 0 x 10 0 Vendor name 7 bytes BALLUFF 0 x 11 0 Vendor text 15 bytes www balluff com 0 x 12 0 Product name 37 bytes BIC 1I0 IAA50 M30MI3 SM4A4A 0 x 13 0 Product ID 7 bytes BIC0053...

Страница 14: ...cable length PUR for remote open cable end BCC M415 0000 1A 003 PX0434 xxx XXX cable length 9 2 Installation accessories Description Description Fig BES 30 0 BS 1 BES 30 HW 1 9 3 Active components De...

Страница 15: ...Balluff inductive Coupler Base 1 Remote 2 Technology PNP variant 24 V power class 500 mA IA 11 bytes Housing shape M30x1 5 Housing material M brass and length SM4A5A Connector M12 axial Number of pin...

Страница 16: ...www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Deutschland Tel 07158 173 0 Fax 07158 5010 balluff balluff de Nr 885425 726 E 04 127519 Edition L18 Replaces Edition 1203 Subject...