Страница 1: ...analogue input signals instruction manual Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Phone 49 0 71 58 1 73 0 Fax 49 0 71 58 50 10 Servicehotline 49 0 7158 1 73 3 70 E Mail balluff...

Страница 2: ...s business interruption or other pecuniary loss arising out of or inability to use this product All our products are warranted against defective material and workmanship for a period of two 2 years fr...

Страница 3: ...s 6 4 1 General instructions 6 4 2 Hints against noisy enviroment 7 4 3 Connection and pin assignment 7 4 4 Connection of input signals 8 4 4 1 Input voltage 0 10 V 8 4 4 2 Input current 0 20 mA 4 20...

Страница 4: ...1 Scaling the display range 12 7 2 Tare 13 7 3 Display test 13 7 4 Programming quick reference 14 8 Technical specifications 14 9 Notices 15 Stand 27 03 2003 UM3023A PUB Technische nderungen vorbehalt...

Страница 5: ...ity to customer or any other person or entity with respect to any liablity loss or damage caused or alleged to be caused directly or indirectly by equipment or software sold or furnished by us Read th...

Страница 6: ...tection against humidity dust and high temperatures at the place of operation 3 2 Panel mounting 3 2 1 Panel for switch board For mounting in switch boards insert the case into the panel cutout 92 0 0...

Страница 7: ...ly without voltages applied Cords must be provided with sleeves Attention must be paid that the power supply voltage applied will agree with voltage noticed at the Type plate The instrument has no pow...

Страница 8: ...advisable To use shielded cables The wiring of shields and ground 0V should be star shaped The distance to interference sources should be as long as possi ble If necessary protective screen or metal e...

Страница 9: ...3 Signal ground 6 Supply voltage 4 4 Connection of input signals 4 4 1 Input voltage 0 10 V 4 4 2 Input current 0 20 mA 4 20 mA 4 5 Connection of power supply voltage 3 0 V 1 2 3 1 10 V 1 2 3 3 2 0 4...

Страница 10: ...onfiguration by programming Attention When the instrument is built in a machine and the customer wants to change the configuration attention must be paid that no damage will occur to the machine 6 Pro...

Страница 11: ...y the buttons on the front Push button Function P button Selection of parameter button Increase of number of parameter parameter button Decrease of number of parameter parameter button select the disp...

Страница 12: ...on Confirm the parameter by pressing the P button The display shows the programming level and the number of the parameter e g 0 04 parameter 4 7 1 Programming level for configuration 0 00 Param Descri...

Страница 13: ...input current 1mA or 3mA the display range exceeds the possible minimum 999 the parameter P0 03 has the value 3 decimal point after the first decade X XXX in this case is the display of negative valu...

Страница 14: ...0 04 had to be set to 1 Erase the tare value push the button for ca 3 seconds After this reset the untared value is displayed 7 3 Display test Activating the display test will drive all segments of t...

Страница 15: ...t negative Values Operation keyboard design front membrane with push buttons Power supply 24 V 20 DC isolated power consumption max 65 mA Case 96 x 48 x 60 mm depth 72 mm incl screw terminal protectio...

Страница 16: ...9 Notices 9 Notices 15...