144
english
7.8
Device Access Locks
7.8.1 Description
With
Device Access Locks
, the device can be locked for
certain types of configuration access to prevent changes
to the parameters.
This functionality is defined in the IO-Link standard and is
implemented according to Version 1.1.3.
7.8.2 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data Storage
Default
Device Access Locks
0x000C (12)
0
R/W
2 bytes
UINT16
Yes
0
Tab. 7-24: Device Access Locks – ISDU
The parameter is accessed via subindex 0. Parameter
access can be locked by setting the corresponding bits:
Bit
Access Method/Interface
Access
Description
0…15
n/a
–
–
Tab. 7-25: Device Access Locks – Parameter access
7
System functions (continued)
BCM R16E-004-CI0 _ - _ _ , _-S4
Condition Monitoring Sensor
Содержание BCM R16E-004-CI01-S4 Series
Страница 2: ...www balluff com...
Страница 3: ...BCM R16E 004 CI01 _ _ _ S4 BCM R16E 004 CI02 _ _ _ S4 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 165: ...BCM R16E 004 CI01 _ _ _ S4 BCM R16E 004 CI02 _ _ _ S4 Configuration guide english...
Страница 166: ...www balluff com...