
72
english
5
Primary device functions (continued)
Object ID
Name
Description
Direction
Spectrum X-axis data
0xA0D0
PD Z Band 13 Mantissa of the calculated vibration RMS in Band 13 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0D1
PD Z Band 14 Mantissa of the calculated vibration RMS in Band 14 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0D2
PD Z Band 15 Mantissa of the calculated vibration RMS in Band 15 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0D3
PD Z Band 16 Mantissa of the calculated vibration RMS in Band 16 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0D4
PD Z Band 17 Mantissa of the calculated vibration RMS in Band 17 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0D5
PD Z Band 18 Mantissa of the calculated vibration RMS in Band 18 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0D6
PD Z Band 19 Mantissa of the calculated vibration RMS in Band 19 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0D7
PD Z Band 20 Mantissa of the calculated vibration RMS in Band 20 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0D8
PD Z Band 21 Mantissa of the calculated vibration RMS in Band 21 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0D9
PD Z Band 22 Mantissa of the calculated vibration RMS in Band 22 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0DA
PD Z Band 23 Mantissa of the calculated vibration RMS in Band 23 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0DB
PD Z Band 24 Mantissa of the calculated vibration RMS in Band 24 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0DC
PD Z Band 25 Mantissa of the calculated vibration RMS in Band 25 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0DD
PD Z Band 26 Mantissa of the calculated vibration RMS in Band 26 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0DE
PD Z Band 27 Mantissa of the calculated vibration RMS in Band 27 of amplitude spectrum
analysis for Z-axis. The unit is g.
Input
0xA0DF
PD Scaler Z
Mantissa of the calculated vibration RMS in Bands of amplitude spectrum
analysis for Z-axis. Scientific notation is used to represent the calculated values.
the scaler value is recalculated every time when the process data is updated. The
scaler value is adjusted to the biggest calculated vibration RMS value for Z-axis.
Example:
Calc.vibr. RMS in Band 1 for Z-axis = PD Z Band 1×10
PD Scaler Z
Input
Tab. 5-14: Vibration Frequency Domain Analysis process data input
– amplitude spectrum RMS values
BCM R16E-004-CI0 _ - _ _ , _-S4
Condition Monitoring Sensor
Содержание BCM R16E-004-CI01-S4 Series
Страница 2: ...www balluff com...
Страница 3: ...BCM R16E 004 CI01 _ _ _ S4 BCM R16E 004 CI02 _ _ _ S4 Konfigurationsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 165: ...BCM R16E 004 CI01 _ _ _ S4 BCM R16E 004 CI02 _ _ _ S4 Configuration guide english...
Страница 166: ...www balluff com...