16
english
6
IO-Link interface (continued)
Index assignment of switching channels
Channel number
Assigned channel Comment
0 (0x00)
BDC1
Binary data channel 0 (
default
)
1 (0x01)
BDC1
Binary data channel 1 (Bit 0 in PD)
2 (0x02)
BDC2
Binary data channel 2 (Bit 1 in PD)
3 (0x03)
BDC3
Binary data channel 3 (Bit 2 in PD)
255 (0xFF)
BDC1…3
Return all switching channel settings to factory default.
Tab. 6-11: Index assignment of switching channels
Returning all switching channel settings to factory
default
Index
Subindex Access
Value
Hex. Dec. Hex. Dec.
1.
Select switching channel.
003A 58
00
0
Read/Write Channel number
1)
2.
Return all settings of the previously selected switching
channel to factory settings
2)
.
0002 2
00
0
Write only
0x4E
1)
See Tab. 6-11 on page 16, hexadecimal value
2)
See chapter Factory settings on page 17
6.12 Teach-in of the measuring range
The start and end points of the curve (Slmin and Slmax)
can be defined by teaching in to indicate the gradient
progress and gradient value of the curve.
Teach-in process of the measuring range
Index
Subindex Access
Value
Hex. Dec. Hex. Dec.
1.
Activate the measuring range settings.
003A 58
00
0
Read/Write 0xC0
2.
Move target to new Slmin.
3)
3.
Temporarily save the current distance as Slmin.
0002 2
00
0
Write only
0x4B
4.
Move target to new Slmax.
4)
5.
Temporarily save the current distance as Slmax.
0002 2
00
0
Write only
0x4C
6.
Apply and activate values for the new measuring range Slmin/
Slmax.
0002 2
00
0
Write only
0x4D
3)
Within the original linear range
4)
Within the original linear range and at least
1.1 mm (BAW M12MI-BLC35C-S04G) or
2.3 mm (BAW M12MH-BLC70G-S04G) away from Slmin
The teach-in process has no time limit.
The minimum distance from start to end point:
– BAW M12MI-BLC35C-S04G: 1.1 mm
– BAW M12MH-BLC70G-S04G: 2.3 mm
The start point Slmin is initially saved temporarily and can
then be overwritten any number of times.
If the target leaves the measuring range during
teach-in, the error message
TEACH_STATE_ERROR is shown.
If the measuring range is changed by teach-in, any
previously saved switching positions (BDCs) are deleted.
The new curve offset and gradient value set by teach-in
can be read out as described in Tab. 6-7 on page 12.
BAW M12MI-BLC35C-S04G and BAW M12MH-BLC70G-S04G
Inductive Linear Position Sensor
Содержание BAW M12MI-BLC35C-S04G
Страница 1: ...BAW M12MH BLC70G S04G BAW M12MI BLC35C S04G Betriebsanleitung deutsch...
Страница 2: ...www balluff com...
Страница 21: ...BAW M12MH BLC70G S04G BAW M12MI BLC35C S04G User s Guide english...
Страница 22: ...www balluff com...
Страница 41: ...BAW M12MH BLC70G S04G BAW M12MI BLC35C S04G Manual de instrucciones espa ol...
Страница 42: ...www balluff com...
Страница 61: ...BAW M12MH BLC70G S04G BAW M12MI BLC35C S04G Notice d utilisation fran ais...
Страница 62: ...www balluff com...
Страница 81: ...BAW M12MH BLC70G S04G BAW M12MI BLC35C S04G Manuale d uso Italiano...
Страница 82: ...www balluff com...