22
english
8
Menu structure (continued)
Signal Delay Mode
With Signal Delay Mode, the current mode of the signal
delay function can be selected.
Value
Meaning
Description
Del:Delay
Delay
On, Off and On-/Off delay
function
Del:OneSh One-Shot
One-Shot function
Tab. 8-6: Signal Delay – Signal Delay Mode
Signal Delay Off-Delay / One-Shot
With Signal Delay Off-Delay / One-Shot, the time for
Off-Delay and One-Shot can be set. The value represents
the time in milliseconds. The value range is between
0 and 10000. A value of 0 represents no delay.
Signal Delay On-Delay
With Signal Delay On-Delay, the time for On-Delay can be
set. The value represents the time in milliseconds. The
value range is between 0 and 10000. A value of 0 repre-
sents no delay.
The parameter has no effect in One-Shot-
Modus.
8.5
Options
8.5.1 Device Access Locks
Description
With Device Access Locks, the device can be locked for
certain types of configuration access to prevent changes
to the parameters:
Local parameterization, except Easy Teach and external
Teach
8.5.2 Easy Teach Mode
This parameter determines which Teach Mode is called up
when the Easy Mode button is pressed (min. 3s).
Value
Description
Off
Off
1-V-T SP1
Single Value Teach SP1
2-V-T SP1
Two Value Teach SP1
Dyn-T SP1
Dynamic Teach SP1
Tab. 8-7: Options – Easy Teach Mode
8.5.3 Display Configuration
Description
The display brightness and the reading direction of the
display can be set. Furthermore, it is possible to configure
how the display behaves in standby and after how long
after the last button press it goes into standby. In standby
mode the signal value is displayed if standby power is set
to “always on”. In “on with touch mode” the display of the
signal value can also be reactivated with the lid closed by
covering the touch area. In standby the display brightness
is reduced.
Especially at high ambient temperatures it is recommen-
ded to set the standby power to “always off” or “on with
touch”.
OPTIONS
OPT Options
LckLocPar
PLC Lock Local Parameter:
Lock OFF*, Lock ON
Easyteach
ETE Off*, 1-V-T SP1, 2-V-T SP1, Dyn-T SP1
Display
DIS Display Settings
Brightness
BRI Lowest, Low, Medium*, High, Highest
Orientation ORT NoRotation*, 180°CW Rot
Stb Visib.
STB always on, always off*, on w.touch
ShdwnTimer SHD Standby-Shutdown-Timer:
5..60*..600 s
Fact.Reset
DEF No*, Yes
BAE SA-OH-059-YI-----
Photoelectric Sensors
Содержание BAE SA-OH-059-YI-DP02
Страница 1: ...deutsch Betriebsanleitung english User s guide BAE SA OH 059 YI DP02 BAE SA OH 059 YI S75G...
Страница 2: ...www balluff com...
Страница 3: ...BAE SA OH 059 YI DP02 BAE SA OH 059 YI S75G Betriebsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 32: ......
Страница 33: ...BAE SA OH 059 YI DP02 BAE SA OH 059 YI S75G User s Guide english...
Страница 34: ...www balluff com...