47
47
E
Protection
ground
Wiring diagram for
BIS C-602-...-ST11
processor with
adapter BIS C-654
PROFIBUS-DP
Supply
voltage,
digital input
Terminal location
and designation
The ground connector should be connected to earth directly or through a RC combination de-
pending on the system (potential counterpoise).
When connecting the bus leads, make sure that the shield has proper connection to connector
housing.
BIS C-602-...-ST11
Schnittstelleninformationen / Anschlusspläne
1
2
3
5
4
X1
, Supply voltage, digital input
X2
, PROFIBUS-
input (male)
1
2
3
5
4
n.c. = do not connect
X3
, PROFIBUS-
output (female)
2
1
4
5
3
Pin
Function
1
VP
2
A
3
DGND
4
B
5
n.c.
Pin
Function
1
+Vs
2
IN
3
Vs
4
+IN
5
n.c.
Connection for
read/write head
BIS C-355/...S92
To use the BIS C-654 adapter the "Select both
heads" function, Example 7, must always be acti-
vated after powering up or after a RESET.
C6_2-019_641365_0506-e.p65
48
48
E
Dimensions,
Weight
Housing
Plastic ABS
Dimensions with read/write head BIS C-65_
ca. 169 × 90 × 35 mm
Dimensions with adapter BIS C-650
ca. 185 × 90 × 35 mm
Weight
ca. 400 g
Ambient temperature
0 °C to + 60 °C
Enclosure rating
IP 65 (with read/write head)
Terminal block
19-pin
Cable entry
2× PG 11 fittings (metal)
Cable diameter
5 to 10 mm
Cable entry
1× PG 9 fittings (metal)
Cable diameter
4 to 8 mm
Conductor size
0.14 to 1 mm
2
with ferrules
0.25 to 0.34 mm
2
Round connector X1 for
V
S
, IN
5-pin (male)
Round connector X2 für
PROFIBUS-DP
input
5-pin (male)
Round connector X3 für
PROFIBUS-DP
output
5-pin (female)
Supply voltage V
S
, input
DC 24 V ± 20 %
Ripple
≤
10 %
Current draw
≤
400 mA
PROFIBUS-DP
slave
electrically isolated
Operating
Conditions
Connections
BIS C-602-...-KL2
Enclosure Rating
Electrical
Connections
BIS C-602
Technical Data
Connections
BIS C-602-...-ST11