Quick Start Guide
MN1944 8/05
IMPORTANT NOTE !
This Quick Start Guide is not intended as a replacement for the full installation manual,
MN1942 MicroFlex e100 Installation Manual
, which provides detailed information about the product.
The installation manual is available in PDF format on the supplied Baldor Motion Toolkit CD.
Mounting
MicroFlex e100 is designed to be supported by four M5 screws,
spaced as shown in the diagram.
MicroFlex e100 must be fixed to a smooth vertical metal surface to
ensure effective cooling.
63.5mm
167.7 mm
LT0228A00
Printed in UK
© Baldor UK Ltd
Baldor UK Ltd
Mint Motion Centre
6 Bristol Distribution Park
Hawkley Drive
Bristol, BS32 0BF
Visit www.supportme.net for the latest documentation and software releases.
Mounting
hole centers
Cooling for 6A & 9A models
Effective cooling for the MicroFlex e100 is essential:
* The 3A model requires no additional cooling.
* The 6A model requires additional forced air cooling at 1.0m/s or greater.
* The 9A model requires additional forced air cooling at 2.5m/s or greater.
2
1
Heatsink
Fan
Quoted air velocities are for air originating from below the MicroFlex e100,
passing parallel to the heatsink. With MicroFlex e100 mounted as specified,
quoted air velocities allow full drive rated current at ambient temperatures up
to 45°C.