background image

Quick Start Guide

MN1944 8/05

IMPORTANT NOTE !

This Quick Start Guide is not intended as a replacement for the full installation manual,

MN1942 MicroFlex e100 Installation Manual

, which provides detailed information about the product.

The installation manual is available in PDF format on the supplied Baldor Motion Toolkit CD.

Mounting

MicroFlex e100 is designed to be supported by four M5 screws,
spaced as shown in the diagram.

MicroFlex e100 must be fixed to a smooth vertical metal surface to
ensure effective cooling.

63.5mm

167.7 mm

LT0228A00

Printed in UK

© Baldor UK Ltd

Baldor UK Ltd

Mint Motion Centre

6 Bristol Distribution Park

Hawkley Drive

Bristol, BS32 0BF

Visit www.supportme.net for the latest documentation and software releases.

Mounting

hole centers

Cooling for 6A & 9A models

Effective cooling for the MicroFlex e100 is essential:

* The 3A model requires no additional cooling.
* The 6A model requires additional forced air cooling at 1.0m/s or greater.
* The 9A model requires additional forced air cooling at 2.5m/s or greater.

2

1

Heatsink

Fan

Quoted air velocities are for air originating from below the MicroFlex e100,
passing parallel to the heatsink. With MicroFlex e100 mounted as specified,
quoted air velocities allow full drive rated current at ambient temperatures up
to 45°C.

Отзывы: