Страница 1: ...HMI Operator Panel Installation Operating Manual 2 02 MN1272...

Страница 2: ...ftware on your PC 2 6 Minimum system requirements 2 6 Installation 2 6 Host Communications Setup 2 6 Software Settings 2 8 Panel Setup 2 9 Quick Start 2 12 Section 3 Start Up 3 1 Power Off Checks 3 1...

Страница 3: ...ii Table of Contents MN1272...

Страница 4: ...al or workmanship This warranty is valid if the unit has not been tampered with by unauthorized persons misused abused or improperly installed and has been used in accordance with the instructions and...

Страница 5: ...quipment This equipment may be connected to other machines that have rotating parts or parts that are controlled by this equipment Improper use can cause serious or fatal injury WARNING Be sure all wi...

Страница 6: ...n that conforms to published storage humidity and temperature specifications stated in Section 6 Location Considerations The location of the control is important Installation should be in an area that...

Страница 7: ...moved the gasket should be replaced Figure 2 2 Mounting the Panel Cutout HMI Panel Thick Gasket Thin Gasket 5 Secure the panel to the enclosure using the mounting hardware provided Finger tighten each...

Страница 8: ...for panel operation The panel must always be grounded to protection earth PE Grounding helps limit the effects of noise due to electromagnetic interference on the control system Earth connection is ma...

Страница 9: ...rt connector and pin assignment Pin Description 1 Frame Ground 2 RXD 3 TXD 4 5 V output Max 100mA 5 GND 6 CHA 7 CHB 8 TX 20 mA 9 TX 20 mA 10 RTS 11 CTS 12 RX 20 mA 13 RX 20 mA 14 CHA 15 CHB Use a null...

Страница 10: ...ctors C in Figure 2 8 Be sure the connectors are locked 5 Install the cover and the 2 screws A 6 Install the label shipped with the module in the area B in Figure 2 8 Figure 2 8 Installing the Communi...

Страница 11: ...ograms are running during this installation 2 Place installation Disk 1 in your computer s floppy drive 3 Run A Setup exe if A is your floppy drive or double click the file Setup exe from My computer...

Страница 12: ...ct the COM port you are using then click properties Figure 2 9 4 Be sure the port settings are as Bits per second 9600 Data bits 8 Parity none Stop bits 1 and Flow control Xon Xoff Windows NT 2000 1 P...

Страница 13: ...signer program At the main menu select Options Communications Choose the COM port you will be using and be sure the settings are 9600 1 Stop bit No Parity Click OK when done At the main menu select Pr...

Страница 14: ...ect your settings on the Panel Setup Dialog box Selecting Protection allows you to enter a password Note Another quick way to do this is to retreive panel resources To do this connect and power up the...

Страница 15: ...2 10 Receiving Installation MN1272 Selecting RPT allows Remote Pass Through options to be set Selecting MISC allows some miscellaneous parameters to be set...

Страница 16: ...the main menu select Project Controller Setup Select the control model being used and set the communications for the control The system is now ready for programming Refer to MN1271 for information on...

Страница 17: ...ller being used You are now ready to begin designing the project page Create your own or do the following example Example 1 Use the PC keyboard type the words This is a data value on the first page of...

Страница 18: ...r accuracy workmanship and tightness 5 Verify that all wiring conforms to applicable codes 6 Verify that the panel is properly grounded to earth ground Power On Checks This procedure applies to the al...

Страница 19: ...nformation Help Same as HELP Key Programmable with the Macro Editor Fault Red OFF No failure Battery OK Blink Battery Low ON Hardware Failure detected Fault Green OFF No keys are pressed ON Visual fee...

Страница 20: ...t 4 in Data Entry Mode 1 Digit 1 Digit 1 in Data Entry Mode 8 Digit 8 Digit 8 in Data Entry Mode 5 Digit 5 Digit 5 in Data Entry Mode 2 Digit 2 Digit 2 in Data Entry Mode 9 Digit 9 Digit 9 in Data Ent...

Страница 21: ...he bottom of the display S An example of the diagnostic information displayed is as follows OPT032 501 0 H100 X030 OK Where OPT032 501 Communication module type CANopen 0 H100 X030 Internal codes OK M...

Страница 22: ...data maintained by the battery Replace the battery as follows 1 Turn off the panel disconnect input power cable and the push on ground terminal 2 Remove the 2 screws labeled A holding the rear cover F...

Страница 23: ...hold the symbol until it moves to the lower left corner of the screen 4 Touch and hold the symbol until the indication to touch the key is displayed on the screen 5 Touch and hold the key until the in...

Страница 24: ...e is displayed CANopen Module The CANopen module provides some diagnostic information during operation To access the information do the following S Connect a PC to the RS232 485 port S Start the Desig...

Страница 25: ...5 2 Troubleshooting MN1272...

Страница 26: ...7 Hz 0 075 mm peak 57 500 Hz 1 g IEC 68 2 6 Shock 50 g 11 ms 3 pulses per axis IEC 68 2 27 Keyboard reliability 3 million operations Touch screen technology Resistive Touch screen reliability 1 millio...

Страница 27: ...screen resistive Touch screen No Yes User LED s 5 24 0 System LED s 4 5 5 PC Printer Port No Yes Yes PLC Port Yes Yes Yes AUX Port Yes Yes Yes Programming speed 9600 9600 to 38400 9600 to 38400 Batter...

Страница 28: ...oduct Data 6 3 MN1272 Dimensions KPD007 0 19 5 Cutout 4 29 109 3 78 96 2 36 60 5 86 149 5 35 136 Dimensions are in inches mm KPD008 Cutout 6 93 176 6 41 163 2 8 71 8 66 220 8 15 207 0 19 5 Dimensions...

Страница 29: ...6 4 Specifications Product Data MN1272 Dimensions Continued KPD009 0 19 5 Cutout 4 29 109 3 78 96 2 36 60 5 86 149 5 35 136 Dimensions are in inches mm...