Start Up

 

Your spa will enter 

Priming Mode

 (Pr) after initial start-up 

sequence. During Priming Mode, press 

Jets Button(s)

 

repeatedly to ensure all pumps are free of air. Priming Mode 

will end automatically in 4 minutes. Press a Temperature 

Button to exit Priming Mode manually. When Priming Mode 

ends, Pump 1 will start and the water temperature will appear 

after about a minute. If the water temperature is below the Set 

Temperature, the heater will begin.   

 
Basic Operation 

 

   

Press a 

Temperature Button 

once to see the current 

temperature flash on the LCD (Note that the Set Temperature and 

actual temperature are often different). While the numbers are 

flashing, press a Temperature Button again to change the Set 

Temperature. Press-and-hold for faster adjustment. After the new 

Set Temperature stops flashing (about 10 seconds) the actual 

temperature is displayed and the new Set Temperature is 

programmed. The spa will now adjust to the new Set Temperature.  

 

 

 

The 

Light Button 

turns the Spa Light on and off and is 

also used in conjunction with the Temperature Button(s) to 

navigate the system menus.  

 

Automatic Polling (Standard Mode) 

The pump activates for one minute to check the temperature: every 

30 minutes, if another pump is on, when set temperature is raised.

 

 

Filtration 

To program the filtration cycle, press a “Temperature Button” and 

enter Set Temp Mode. While the Set Temperature is flashing, press 
“Light” repeatedly until “FLTR

1

” appears. Press a “Temp. Button” 

to select Filter One and again to program the Start Time. Press 
“Light” to move onto the “RUN” Time and use the “Temp 
Buttons” to program filter cycle duration. Press “Light” to set the 
Filter Cycle. Press “Light” again to move into “FLTR

2

” and press a 

“Temp. Button” to select and program the second filter cycle in the 
same way.  

The two filtration cycles should be programed 12 hours apart for 2 

hours each. It is important to set filter cycles on a pattern. We 

recommend programming cycles at 7am/7 pm and avoiding the 

hours between 10am-5pm.  

 

 
Programming

 

Navigating the deeper menu structure is done with only 2 or 3 

buttons. Press a “Temperature” Button once to see the temperature 

flash. Pressing the “Light” Button while the Set Temperature is 

flashing enters the menu. Continually pressing “Light” to proceed 

through the Menu Choices (TEMP, MODE, TIME, FLIP, LOCK, 

HOLD, FLTR

1

, FLTR

2

,

 PREF, UTIL). Pressing a “Temperature” 

Button while any menu item is showing will edit it directly or 

begin an editing sequence. After editing, allow 10-30 seconds to 

return the panel to normal operation and display the spa status.  

 

Ready and Rest Modes 

READY 

Mode will circulate water every 1/2 hour using Pump 1 

Low to maintain a constant water temperature, heat as needed, and 

refresh the temperature display (polling). 

 

REST

 Mode will only allow heating during programed filter 

cycles. Since polling does not occur, the temperature display may 

not show a current temperature until the filtration pump has been 

running for a minute or two. READY/REST Mode may appear 

when Jet 1 is activated.  

 
Dual Temperature Ranges 

This system incorporates two temperature range settings with 

independent set temperatures. The High Range is indicated by the 

display 

and can be set from 80*F-104*F. The Low 

Range is indicated by the display 

 and can be set from 

50*F-99*F. Low Range is economical during non-use periods. 

More specific Temperature ranges may be determined by the 

manufacturer.  

 