Diagnostic Messages

 

 

Message

 

Meaning

 

Action Required

 

 

No message on display. 

The control panel will be disabled until power returns. Spa settings 

 

Power has been cut off to the spa. 

will be preserved until next power up. 

 

Temperature unknown. 

After the pump has been running for 1 minute, the current water 

 

 

temperature will be displayed. 

 

“Overheat” - The spa has shut down.* One of the 

DO NOT ENTER THE WATER. Remove the spa cover and allow 

 

sensors has detected  118°F/47.8°C  at the heater. 

water to cool. Once the heater has cooled, reset by pushing any 

 

 

button. If spa does not reset, shut off the power to the spa and call 

 

 

your dealer or service organization. 

 

“Overheat” - The spa has shut down.* One of 

DO NOT ENTER THE WATER. Remove the spa cover and allow 

 

the sensors has detected  that the spa water is 

water to cool. At 107°F/41.7°C, the spa should automatically  reset. 

 

110°F/43.5°C. 

If spa does not reset, shut off the power to the spa and call your 

 

 

dealer or service organization. 

 

Spa is shut down.* The sensor that is plugged into 

If the problem persists, contact your dealer or service organization. 

 

the Sensor “A” jack is not working. 

(May appear temporarily  in an overheat condition.) 

 

Spa is shut down.* The sensor that is plugged into 

If the problem persists, contact your dealer or service organization. 

 

the Sensor “B” jack is not working. 

(May appear temporarily  in an overheat condition.) 

 

Sensors are out of balance.  If alternating with spa 

If the problem persists, contact your dealer or service organization. 

 

temperature, it may just be a temporary condition.   

 

If flashing by itself, spa is shut down.* 

 

 

A significant difference between temperature 

If the water level is normal, make sure all pumps have been primed. 

 

sensors has been detected.  This could indicate a 

If problem persists, contact your dealer or service organization. 

 

flow problem. 

 

 

Persistent  low flow problems.  (Displays on the 

Follow action required for     message. Heating capability  of the 

 

fifth occurrence of     message within 24 hours.) 

spa will not reset automatically;  you may press any button to reset. 

 

Heater is shut down, but other spa functions 

 

 

continue to run normally. 

 

 

Possible inadequate  water, poor flow, or air 

If water level is normal, make sure all pumps have been 

 

bubbles in detected in the heater.  Spa is shut down 

primed. Press any button to reset. This message will reset 

 

for 15 minutes. 

within 15 minutes. If problem persists, contact your dealer or 

 

 

service organization. 

 

Inadequate water detected in heater. (Displays on 

Follow action required for  message. Spa will not automatically 

third occurrence of      message.) Spa is 

shut down.* 

 

“Ice” - Potential freeze condition  detected. 

 

 

*-Even when spa is shut down, some 
equipment will turn  on if freeze protection is 
needed. 

reset. Press any button to reset manually. 

 

 

No action required. All equipment will automatically activate 
regardless  of spa status. The equipment stays on 4 minutes after the 
sensors detect that the spa temperature  has risen to 45°F/7.2°C or 
higher. An optional  freeze sensor may be added to protect against 
extraordinary  freeze conditions.  Auxiliary freeze sensor protection  is 

advisable is colder climates.  See your dealer for details.

 

Warning!  Shock Hazard! No User Serviceable  Parts.

 

Do not  attempt  service  of  this  control  system.  Contact  your  dealer  or service  organization  for  assistance.  Follow  all owner’s manual  power 
connection  instructions.  Installation  must be performed by a licensed electrician and all grounding connections must be properly installed.

  