Balboa Instruments E2P-EL2001M3-YCAJ Скачать руководство пользователя страница 4

54464_02-97_A

RED AC

WHT AC

J

5

3

J23

J19

J43

J48

K12

U4

J

5

0

J

5

2

BLK AC

J66

J6

5

J63

J64

J42

J

5

4

J

5

6

J

55

J2

5

J

5

7

J26

TB1

CLASS G

FUSE 30A

C

LA

SS

G

F

US

E 30A

F6

F7

F4

K4

W1

F2

K7

T1

HTR2

HTR1

FUSE
0.3A 2

5

0V

K6

K8

G

R

B

W

J79

J

J46

J4

5

J81

12VAC

ADCM

J37

J37

J4

J7J7

J74

W8

1

2

3

FUSE
3A 2

5

0V

TORQUE
RANGE
FOR TB1:
27-30 IN. LBS.

HOT

BLA

C

K

NEUTRAL

WHITE

H

OT

R

ED

Balboa

J11

J11

J8

J8

BARCODE

G

R

B

W

W

W

J12

J14

W

13

W

12

K13

W

2

0

W1

5

BALBOA INSTRUMENTS, INC.   MADE IN U.S.A.

EL2000 TC MACH III  COPYRIGHT 200

5

P/N 22896 REV B

K

10

J2

MAIN
PANEL

MAIN
PANEL

MAIN
PANEL

AUX
PANEL

AUX
PANEL

J9

J

5

J6

K3

J3

K2

W2

F

5

W9

W7

REMOTE

K11

K9

J1

K1

G

R

B

W

G

R

B

W

G

R

B

W

J86

J80

J60

J60

J6

9

J2

0

J1

0

FUSE 10A 2

5

0V

J39

J7

1

J7

0

J98J98

J89

J91

J1

7

J1

5

J13

J83

J22

J24

J8

2

J3

6

TST

SENS. A

SENS. B VAC

EXT. 2SP PUMP 3

EXT. RLY

AUX. F

J72

CFG

SWITCHBANK A

SWITCHBANK B

J90

J977

G

R

B

W

J8

5

J8

5

J8

5

G

R

B

W

J6

J3

J2

W12

K1

F10A 2

5

0V

F

5

X-B
PN 53310

Blower

RT

C

 Enabled

4.0 kW

A.V.

Use AUX Board 

for Blower

With 2-Speed P2

Use X-B Expander

for Blower

With 2-Speed P2

2-Spd P2

Ozone

C

irc.Pump

12V Light

Spa

Light

2-Spd P1

Wiring Configuration and DIP Settings

Setup 1 (As Manufactured)

• 240V Pump 1, 2-Speed
• 240V Pump 2, 2-Speed
• 240V Blower

• 240V Circ Pump
• 120V Ozone
• 12V Spa Light

• 120V Audio\Visual (Stereo)
• 240V 4.0kW Heater
• ML900, ML700, or ML400 Main Panel

120 Volt Connections

240 Volt Connections

Black AC Jumpers 

12 Volt Connections

Relay Control Wires

Wiring Color Key

Typically Line voltage

Typically Line voltage for 2-speed pumps

Neutral (Common)

Ground

Note flat sides in connector

Connector Key

WARNING: 

Main Power to system should be turned OFF BEFORE adjusting DIP switches.

WARNING: 

Persistent Memory (A12) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)

Switchbank A 

Switchbank B 

A2, Low Amp 

A5, Degrees F 
A6, Short Timeouts 

A9/A10,
No Circ Pump 

A9/A10,
No Circ Pump 

A1, Test Mode OFF 

A3, Filter by Time 
A4, 12 Hr Time 

A7, Cleanup Cycle OFF 
A8, 1Hr O3 Supress OFF

A12, Memory Retained

B1, Pump 2 2-Speed 
B2, Pump 2 Disabled 

B3, Blower Disabled 

B4, No Fiber/Wheel
B5, Pump 3 Disabled 
B6, Panel Scrunching OFF

100
114

28

SSID #

J37

3

2

1

12 V

Light

J91

RTC

Enabled

(Not Jumpered)

B3, Blower Enabled 

B2, Pump 2 Enabled 

A11, O3 w/ P1 Low

and P1 is 2-Spd

A2, High Amp 

J15

J83

J22

AUX.F

SENS. A

TST

CFG

When the Logic Jumper is not installed on J83 (CFG),
DIP Switch Settings are enabled.
DIP Switches will then operate as shown below.

Содержание E2P-EL2001M3-YCAJ

Страница 1: ...A pdf 11 27 2006 Template used 40573 v28_A pdf 11 22 2006 9XcYfX ejkild ekj Jpjk d GE System Model E2P EL2001M3 YCAJ Software Version 28 EPN 2130 Base PCBA PN 53974 03 PCB EL2000 PN 22896 Rev B Base P...

Страница 2: ...eo System Connects to A V terminal J4 U4 ADCM W12 MAIN PANEL MAIN PANEL MAIN PANEL AUX PANEL AUX PANEL J6 J3 W2 REMOTE J86 J80 J69 J20 J10 J39 J71 J70 J17 J15 J13 J83 J22 J24 J82 J36 SENS A SENS B VAC...

Страница 3: ...is must be corrected before you can reset Persistent Memory The switch numbers jumpers or configuration settings displayed after are ones with which the system has found a configuration problem For ex...

Страница 4: ...n and DIP Settings Setup 1 As Manufactured 240V Pump 1 2 Speed 240V Pump 2 2 Speed 240V Blower 240V Circ Pump 120V Ozone 12V Spa Light 120V Audio Visual Stereo 240V 4 0kW Heater ML900 ML700 or ML400 M...

Страница 5: ...mode Pump 1 is two speed Ozone is ON with circ pump A12 Persistent memory reset normally off used when spa is powering up Circ Pump A9 A10 Behavior OFF OFF No Circ Pump or Circ Pump not plumbed w heat...

Страница 6: ...1 2 3 4 5 6 7 8 9 RED AC WHT AC J53 J23 J19 J43 J48 K12 U4 J50 J52 BLK AC J66 J65 J63 J64 J42 J54 J56 J55 J25 J57 J26 TB1 CLASS G FUSE 30A CLASS G FUSE 30A F6 F7 F4 K4 W1 F2 K7 T1 HTR2 HTR1 FUSE 0 3A...

Страница 7: ...n replace the X P in cases where branch circuit protection is needed for high amperage devices that would over burden power input fuse F7 1 B on the main PCBA This allows J6 on the X P231 to connect d...

Страница 8: ...determines voltage Ozone Connector Voltage The EL circuit board is factory configured to deliver a preset voltage 120V or 240V to the on board ozone connector J9 See the ratings table on the wiring d...

Страница 9: ...er J91 on Main PCBA must be OFF 1 pin only Heat Jets Aux Temp Light ML400 PN 52684 with Overlay PN 11345 Connects to Main Panel terminal J70 J71 or J72 RTC Jumper J91 on Main PCBA must be ON both pins...

Отзывы: