Balanced Audio Technology VK-30 Скачать руководство пользователя страница 1

 

1

 

 

 

 

 
 

VK-30 

 

WARRANTY REGISTRATION FORM

 

 
 

 

Unit Serial Number:  _______________________________________ 
 
Customer Name: 

_______________________________________ 

 
Address:  

 

_______________________________________ 

 
 

 

 

 

_______________________________________ 

 
Date of Purchase: 

_______________________________________ 

 
 
Purchased From: 

 

 
 

Dealer Name: 

_______________________________________ 

 
 

Address: 

 

_______________________________________ 

 

 

 

 

 

 

 

 

_______________________________________

 

 

 

IMPORTANT NOTE: 
 

In order to receive the full five year product warranty, please mail this 

completed form together with a copy of your sales receipt to Balanced Audio 
Technology at the address below, within thirty days of purchase. 

Failure to do so will result in the product being warrantied for one year 

from the date of manufacture. 

 
 

1300 First State Blvd. Suite A   W ilmington, DE 19804 

Tel: 302-999-8855  Fax: 302-999-8818

 

Содержание VK-30

Страница 1: ...____________________________ Address _______________________________________ _______________________________________ IMPORTANT NOTE In order to receive the full five year product warranty please mail...

Страница 2: ...2 VK 30 Vacuum Tube Balanced Stereo Preamplifier Owner s Manual 1300 First State Blvd Suite A Wilmington DE 19804 Tel 302 999 8855 Fax 302 999 8818...

Страница 3: ...lection 7 VOLUME knob 7 DISPLAY format 8 FUCTION button 8 DISPLAY ON OFF function 9 MUTE function 9 VK 30 PROGRAMMABLE FUNCTIONS 10 Parameter Definitions 11 PROGRAMMING THE VK 30 11 BALANCE adjustment...

Страница 4: ...re DO NOT operate with the cover removed DO NOT expose to rain or moisture DO NOT defeat the ground power plug DO NOT replace fuse with anything other than the same type and rating as supplied by the...

Страница 5: ...e For the VK 30 use the Main 1 XLR Output for connection to your balanced power amplifier The Output 2 is configured as an RCA connector output Single Ended Components Single ended components have RCA...

Страница 6: ...automatically go through a gentle power on sequence This sequence takes 50 seconds during which time the display and the Standby LED will be flashing indicating the status of the unit 1 The number on...

Страница 7: ...les are changed or any other system configuration changes are being made This function is also accessible via the VK R3 remote control LED OFF Unit in Play mode LED ON Output Muted INPUT selection but...

Страница 8: ...4 Volume setting three digits with the full range of 000 to 140 See programming section on Maximum Volume Setting FUNCTION Button This button puts the unit in its programming mode In addition to its n...

Страница 9: ...ront panel Depressing this button again will return the unit to its normal operation and turn the mute LED off When the unit is powered up it automatically self mutes until the proper operating points...

Страница 10: ...default set of parameters stored in its memory This set of parameters is usable for many applications The default set includes the following parameters BALANCE ZERO RELATIVE VOLUME ZERO PHASE Non Inve...

Страница 11: ...o and Inverting PROGRAMMING THE VK 30 NOTE It is important to note here that all the functions described below are accessible either through the front panel controls or via the VK R3 remote control Th...

Страница 12: ...olume offset will then read 20 The user can later select the PH1 input and using it as the reference program the AUX1 input to be 10 counts lower than the PH1 input Effectively the volume offset from...

Страница 13: ...unction button NOTE In the LAST mode the state of the Phase switch will be the same as used the last time for that particular input MAXIMUM gain programming It may be desirable to limit the allowable...

Страница 14: ...on button DISPLAY MODE programming The volume display of the VK 30 can be switched to work in any of the following three modes CNTS Relative volume counts with the range of 000 to 140 DBU Decibel read...

Страница 15: ...The first character of the input name will start blinking Use the volume control knob or the remote control Volume Up Down buttons to select the desired character The characters are organized in the...

Страница 16: ...s The Mute LED on the VK 30 front panel will reflect the status of the Mute circuit Fade Pressing the FADE button on the VK R3 remote control will cause the volume to smoothly decay over the period of...

Страница 17: ...fuse in the VK 30 is an indication of a serious problem If a replacement fuse fails as well no further attempts should be undertaken Please contact the factory for professional service The proper fuse...

Страница 18: ...by anyone other than Balanced Audio Technology or its specifically authorized agents 5 Remedy If this product contains a materials manufacturing or workmanship defect that cannot be repaired at the d...