Baker Hughes PanaFlow Z1G Скачать руководство пользователя страница 18

Table 2: RS485 cable connections

TB Pin #

Signal description

1

RS485+

2

RS485-

3

COM

4

Not Used

5

Not Used

4.  If wiring of the unit has been completed, reinstall the rear  

 

cover on the enclosure and tighten the set screw.

Proceed to the next section to continue the wiring of the 

PanaFlow Z1G/Z2G Process Gas Flowmeter

.

2.4.5   Wiring the option cards

The 

PanaFlow Z1G/Z2G Process Gas Flowmeter

 can 

accommodate two option cards one in Slot 1 and other 

option card in Slot 2. The following option card functions are 

available only in certain combinations.
•  Analog Inputs (Slot 1)
•  RTD Inputs (Slot 1)
•  Modbus Communications (Slot 2)
•  HART Communications (Slot 2)
•  Foundation Fieldbus Communications (Slot 2)

Figure 14 on page 15 

shows the connection labels for the 

available option cards. Wiring any option card installed in 

Slot 1 requires completion of the following steps:

Attention! 

To meet CE Mark requirements for all units 

intended for use in the EU or in high electrical 

noise environments, all electrical cables 

must be installed as described in 

Appendix 

A, “CE Mark Compliance and High Noise 

Environments”.

1.  Disconnect the main power and remove the rear cover.
2.  Install a cable clamp in the chosen conduit hole on the 

side of the electronics enclosure and feed a standard 

twisted-pair cable through this conduit hole.

3.  Locate the 12-pin terminal block in Figure 13 on page 14 

and wire the option card as indicated on the label inside 

the rear cover (see Figure 9 on page 7). Secure the cable 

clamp.

IMPORTANT:

If you have multiple flow transmitters, because of the 

attached wiring label, all rear covers must remain with 

their original meters!

4.  If wiring of the unit has been completed, reinstall the rear 

cover on the enclosure and tighten the set screw.

IMPORTANT:

Prior to use, the option card must be set up and calibrated.

For more specific instructions on particular option cards, 

proceed to the appropriate section(s) that follow.

2.4.5.1  Wiring a 4-20 mA analog inputs option 

 card

To calculate standard flow rates, the 

PanaFlow Z1G/Z2G 

Process Gas Flowmeter

 requires accurate temperature and 

pressure data from the measurement site. Transmitters 

installed in the flowcell can provide this information via an 

optional4-20 mA analog inputs option card. This option 

card includes two or four isolated 4-20 mA analog inputs 

(designated as A, B, C and D), each of which includes a 24 

VDC power supply for loop-powered transmitters. Either 

input may be used to process the temperature signal, while 

the other input is used to process the pressure signal.

IMPORTANT:

To properly enter programming data into the meter, it 

is necessary to know which input is assigned to which 

process parameter.

The analog inputs, which have an impedance of 118 Ω, should 

be connected with standard twisted-pair wiring. Power to 

the transmitters may be supplied either by the integral 24 

VDC power supply on the analog input option card or by an 

external power supply. 

Figure 10 

below shows typical wiring 

diagrams, with and without an external power supply, for one 

of the analog inputs.

INPUT +

+24V

INPUT +

24V

+

IN

24 VDC

POWER SUPPLY

+

– OUT

+ IN

Sensor

– OUT

Sensor

Transmitter

Transmitter

Analog Input

Analog Input

With External Power Supply

With Internal Power Supply

Figure 10: Typical analog input wiring diagrams

Before making any connections, complete the steps in 

“Making the Electrical Connections” on page 10. Then, wire 

the analog inputs as shown on the label in the rear cover 

(see 

Figure 9 on page 7

).

IMPORTANT:

The analog inputs option card can be calibrated with the 

PanaFlow Z1G/Z2G Process Gas Flowmeter’s built-in analog 

outputs.  However, be certain that the analog outputs have 

been calibrated first.

10

Содержание PanaFlow Z1G

Страница 1: ...PanaFlow Z1G Z2G User s manual 910 321 Rev A...

Страница 2: ...ii...

Страница 3: ...PanaFlow Z1G Z2G Panametrics gas ultrasonic volumetric flow meter User s manual 910 321 Rev A July 2021 iii...

Страница 4: ...no content intended for this page iv...

Страница 5: ...ter tag plate 4 Chapter 2 Installation 6 2 1 Introduction 6 2 2 Lifting instructions 6 2 3 Flowcell location guidelines 7 2 4 Making the electrical connections 7 2 4 1 Wiring the line power 8 2 4 2 Wi...

Страница 6: ...PanaFlow Z1G Z2G process gas flowmeter LCD display 23 4 4 The optional PanaView display 24 4 5 Taking measurements 24 4 5 1 Programming the LCD display 24 4 5 2 Programming the PanaView display 26 4 5...

Страница 7: ...nd on our website at the following link https www bakerhughesds com sales terms conditions Typographical conventions Note These paragraphs provide information that provides a deeper understanding of t...

Страница 8: ...ure that unauthorized personnel cannot gain access to the operation of the equipment Environmental compliance RoHS The PanaFlow Z1G Z2G Process Gas FlowMeter fully complies with RoHS regulations Direc...

Страница 9: ...no content intended for this page 1...

Страница 10: ...Path or 2 Path configuration For the 2 Path configuration the measurement paths are located either at Diametrical path or at Midradius configurations In addition to the flow transducers the PanaFlow Z...

Страница 11: ...anges material list WCB LCB CF8 CF8M CK3MCuN CD3MWCuN 2 Transmitter Electronics 3 Magnetic Stylus for Transmitter Keypad 4 Mounting Adapter Transmitter for local mount only 5 Transducers Inserts The m...

Страница 12: ...e The Specification Tag Plate see Figure 3 contains information pertaining to the build and test of the spool such as spool nominal size flange rating wall thickness material dry weight including tran...

Страница 13: ...to the transmitter and includes the configuration per the model information detailed on the Model Tag Plate This tag plate also contains the hazardous area certification information for the transmitt...

Страница 14: ...d as described in Appendix A CE Mark Compliance and High Noise Environments 2 2 Lifting instructions Use proper lifting techniques when moving the PanaFlow Z1G Z2G Process Gas Flowmeter No lifting hoo...

Страница 15: ...of conformity and EC type design certificates Make sure the difference between the inside diameter of the pipe and that of the PanaFlow Z1G Z2G Process Gas Flowmeter does not exceed 0 5 as changes in...

Страница 16: ...length 0 5 in 1 cm shorter than the ground lead This ensures that the ground lead is the last to detach if the power cable is forcibly disconnected from the meter 2 Install a cable clamp in the condu...

Страница 17: ...Process Gas Flowmeter is equipped with a standard RS485 serial interface This serial port will be used to communicate with PC DCS system In addition the PanaFlow Z1G Z2G Process Gas Flowmeter can rec...

Страница 18: ...set screw IMPORTANT Prior to use the option card must be set up and calibrated For more specific instructions on particular option cards proceed to the appropriate section s that follow 2 4 5 1 Wirin...

Страница 19: ...mends using 24 gauge 24 AWG twisted pair wire with a characteristic impedance of 120 and 120 termination at each end of the communications line Note The Modbus option card provides its own RS485 conne...

Страница 20: ...W A A 0 52 13 DETAIL A 3 4 NPT 1 4 20 UNC 2B 1 50 1 00 0 28 7 0 25 6 4PLCS 10 32 EXTERNAL GROUND SCREW 7 PLCS 3 4 NPTF 52 98 208 38 NOTES 1 ALL DIMENSIONS ARE REFERENCE 2 WEIGHT 10 LB 4 5 KG AL 25 DET...

Страница 21: ...Figure 12 Remote mount electronics transducer and preamplifier wiring ref dwg 702 731 732 13...

Страница 22: ...TION LINE POWER CONNECTION NEUTRAL CONNECTION EARTH GROUND CONNECTION 1 CH1UP CH1 TRANSDUCER CONNECTION TERMINAL BLOCK 3 CH1RTN 2 CH1RTN 4 CH1DN PIN 1 PIN 3 2 1 CH2UP CH2 TRANSDUCER CONNECTION TERMINA...

Страница 23: ...12 10 7 8 6 5 3 4 Pin 1 2 12 11 10 9 8 7 2 4 5 6 3 Pin 1 N R A H F T I C O NOTE R RTD Input A Standard Alarm H Hermetic Alarm F Frequency Output T Totalizer Output I Current Input C Current Output O...

Страница 24: ...les Display text output and graphs of live measurement data Create custom templates for displaying text graph and log data Interface with multiple Panametrics instruments This chapter focuses on progr...

Страница 25: ...wing steps 1 In the Keypad Program scroll to PROG and press 2 In the PROG menu scroll to GLOBL and press 3 In the Global PROGRAM menu scroll to SYSTM and press 4 Scroll to the desired System Units sel...

Страница 26: ...urst to activate the channel path and press Note Burst is automatically selected for a 1 Channel meter 4 Scroll to one of the measurement methods described below and press Skan Only is the preferred t...

Страница 27: ...g mass flow units 1 Scroll to the desired Mass Flow units for the flow rate display and press The available units for this prompt are determined by the selection made at the System Units prompt see Ta...

Страница 28: ...no content intended for this page 20...

Страница 29: ...DOT Dec Digits LB Mass Totals KLB MMLB TONS KG TONNE 0 1 2 3 Mass Dec Digits Metric ACF English KACF MMACF SCF KSCF MMSCF ACM KACM MMACM SCM KSCM MMSCM Volumetric Units 1 Channel Units 2 Channel Units...

Страница 30: ...no content intended for this page 22...

Страница 31: ...analog device to read the PanaFlow Z1G Z2G Process Gas Flowmeter analog output At least one of the above display options must be installed in order to obtain flow rate readings from the meter Immediat...

Страница 32: ...11 for details on using PanaView and the PanaFlow Z1G Z2G Process Gas Flowmeter analog outputs to obtain the flow rate data 4 5 1 Programming the LCD display Note When you first initialize the PanaFlo...

Страница 33: ...Qup Displays the signal quality for the upstream direction 1200 400 to 400 Qdown Displays the signal quality for the downstream direction 1200 400 to 400 AMPup Displays the value for the signal ampli...

Страница 34: ...nual arrange the open windows in the desired format For this discussion Figure 20 shows the Text Display window in its maximized full screen size Figure 20 The text display window 3 The left pane of t...

Страница 35: ...Window menu see the PanaView Manual 4 5 3 Pausing measurements On occasion you may wish to stop taking measurements With PanaView you can direct the PanaFlow Z1G Z2G Process Gas Flowmeter to pause mea...

Страница 36: ...m of straight pipe run Reynolds Number 5000 and single phase fluids Applications with piping arrangements that induce swirl e g two out of plane elbows may require additional straight run and or flow...

Страница 37: ...s Table 10 Reference drawings Drawing number Drawing reference 712 2158 General arrangement drawing PanaFlow Z1G Z2G Local Mount 712 2160 General arrangement drawing PanaFlow Z1G Z2G Remote Mount Note...

Страница 38: ...no content intended for this page 30...

Страница 39: ...connections have been made seal any unused cable entry holes Note If the instructions in this appendix are followed the unit will comply with the EMC Directive Table 11 Wiring modifications Connection...

Страница 40: ...no content intended for this page 32...

Страница 41: ...n card is installed or changed in the PanaFlow Z1G Z2G Process Gas Flowmeter record the type of card and any additional setup information in the appropriate row of Table 12 below Table 12 Option cards...

Страница 42: ...ord complete and detailed service data for the PanaFlow Z1G Z2G Process Gas Flowmeter in Table 13 below Make additional copies of this table as needed Table 13 Service record Date Description of servi...

Страница 43: ...Table 13 Service record cont Date Description of service Performed by 35...

Страница 44: ...Channel System Channel Label Channel Label Site Channel Msg Site Channel Msg Vol Units Vol Units Vol Time Units Vol Time Units Vol Dec Digits Vol Dec Digits Totalizer Units Totalizer Units Mass Flow M...

Страница 45: ...s Mole Wgt Density Type Fluid Dens Mole Wgt Qact or Qstd Actual Standard Qact or Qstd Actual Standard Fluid Density Fluid Density Mole Weight Mole Weight Global System Meter Message Totalizer Units Sy...

Страница 46: ...NTup 25 Connectors Electrical 7 D DELTA 25 Diagnostics Service record 34 Display data 23 DT M 25 DT S 25 E Electrical connections CE Mark compliance 31 Electrical connectors 7 Error codes 24 F Flow Pr...

Страница 47: ...5 Q Qdown 25 Qup 25 R Registration vii RS485 Serial port Modbus 11 RTD Inputs option card Connecting 10 S Safety Auxiliary equipment vii General issues vii Personal equipment vii Service record 34 Ser...

Страница 48: ...S 25 Typographical conventions vii V VEL 25 Vinst 25 Voltage Input 8 VOLUM 25 W Warranty vii Windows Resizing 26 Tiling 27 Wiring CE Mark compliance 31 Option card See card name Terminal block See blo...

Страница 49: ...no content intended for this page 41...

Страница 50: ...ng a suitably certified threaded plug Modifications to the flameproof enclosure are not permitted The apparatus should be de energized before opening Installation shall be in accordance with the insta...

Страница 51: ...te mount junction box and flow body is rated for an ambient temperature range of 20 C to 60 C when local mounted or 40 C to 60 C when remote mounted 7 The equipment temperature class is dependent on t...

Страница 52: ...below for the AC and DC powered versions 2 Shall appear on the meter as shown below 3 Following marking shall additionally appear on the flowcell PANAMETRICS LLC PANAMETRICS LLC PANAMETRICS LLC panam...

Страница 53: ...RTN CH1 DOWNSTREAM TRANSDUCER ANALOG RTN CH1 DOWNSTREAM TRANSDUCER SIG DESCRIPTION LINE POWER CONNECTION NEUTRAL CONNECTION EARTH GROUND CONNECTION 1 CH1UP CH1 TRANSDUCER CONNECTION TERMINAL BLOCK 3...

Страница 54: ...Certificate was issued by HSB UK Production of PED product is monitored and a Marking Permission certificate is issued by HSB UK Hartford Steam Boiler UK Ltd UK NoBo 2561 Unit 7 Brewery Yard Deva City...

Страница 55: ...to assure that the manufacturing process for our products and the components used within those products do not contain the restricted substances below at levels that exceed the maximum concentrations...

Страница 56: ...tellung III Name Funktion Unterschrift EL 1 2 2a 2b 3 4 5 6 6a 6b 7 8 I II III EN EU DECLARATION OF CONFORMITY No XXXX 1 Product model product product type batch or serial number 2 2a Name and address...

Страница 57: ...ll t s helye s d tuma III n v beoszt s al r s IT DICHIARAZIONE DI CONFORMIT UE N XXXX 1 Modello di prodotto prodotto numero di prodotto tipo lotto o serie 2 2a Nome e indirizzo del fabbricante e se d...

Страница 58: ...antului s u autorizat 3 Prezenta declara ie de conformitate este emis pe r spunderea exclusiv a produc torului 4 Obiectul declara iei identificarea produsului permi nd trasabilitatea dac este necesar...

Страница 59: ...and gas flow measurement Experts in flare management Panametrics technology also reduces flare emissions and optimizes performance With a reach that extends across the globe Panametrics critical measu...

Отзывы: