background image

Tech Field Support & Warranty:

Phone: +1-866-827-5378

[email protected]

bakerhughes.com

Copyright 2021 Baker Hughes Company. All rights reserved. Baker Hughes provides this information on 
an “as is” basis for general information purposes. Baker Hughes does not make any representation as to 
the accuracy or completeness of the information and makes no warranties of any kind, specific, implied or 
oral, to the fullest extent permissible by law, including those of merchantability and fitness for a particular 
purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect, consequential or 
special damages, claims for lost profits, or third party claims arising from the use of the information, whether 
a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make changes in 
specifications and features shown herein, or discontinue the product described at any time without notice or 
obligation. Contact your Baker Hughes representative for the most current information. The Baker Hughes 
logo, Flowgrid, Slamshut and Mooney are trademarks of Baker Hughes Company. Other company names 
and product names used in this document are the registered trademarks or trademarks of their respective 
owners.

BHMY-Flowgrid-SS-1in-IOM-20048D-0221          02/2021

Direct Sales Office Locations

Find the nearest local Channel Partner in your area:

valves.bakerhughes.com/contact-us

valves.bakerhughes.com

Australia

Brisbane

Phone:   +61-7-3001-4319
Perth

Phone:   +61-8-6595-7018
Melbourne

Phone:   +61-3-8807-6002

Brazil

Phone:  +55-19-2104-6900

China

Phone:  +86-10-5738-8888

France

Courbevoie

Phone:  +33-1-4904-9000

India

Mumbai

Phone:  +91-22-8354790

New Delhi

Phone:  +91-11-2-6164175

Italy

Phone:  +39-081-7892-111

Japan

Tokyo 

Phone:  +81-03-6871-9008

Korea

Phone:  +82-2-2274-0748

Malaysia

Phone:  +60-3-2161-03228

Mexico

Phone:   +52-55-3640-5060

Russia

Veliky Novgorod

Phone:  +7-8162-55-7898
Moscow

Phone:  +7-495-585-1276

Saudi Arabia

Phone:  +966-3-341-0278

Singapore

Phone:  +65-6861-6100

South Africa

Phone:  +27-11-452-1550

South & Central 

America and the Caribbean

Phone:   +55-12-2134-1201

Spain

Phone:  +34-935-877-605 

United Arab Emirates

Phone:  +971-4-8991-777

United Kingdom

Phone:  +44-7919-382-156

United States

Houston, Texas

Phone: +1-713-966-3600

Содержание Mooney Flowgrid Slam Shut

Страница 1: ...Mooney Flowgrid Slam Shut 1 Valve Instruction Manual Rev D Baker Hughes Data Classification Public...

Страница 2: ...ICULAR REQUIREMENTS FOR OPERATION OF OTHER EQUIPMENT AT THE SITE THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE M...

Страница 3: ...essure protection only 2 under pressure protection only and 3 over and under pressure protection Instructions for the Flowgrid regulator and Pilot are found in separate manuals Product Description The...

Страница 4: ...ng Case Carbon Steel WCB Throttle Plate 17 4 PH or A515 Slam Shut Seat SST Slam Shut Seal Nitrile Flowgrid Diaphragm Nitrile or Viton Flowgrid Spring SST Slam Shut Housing Slam Shut Spring Cases Alumi...

Страница 5: ...hut has all nitrile soft goods VITON The Slam Shut has nitrile static seals and viton dynamic seals and diaphragms MAX INLET Maximum inlet pressure PSIG BAR MIN DIFF Minimum difference in outlet and d...

Страница 6: ...m Shut valve and or Flowgrid regulator should be made by qualified personnel familiar with high pressure piping and pilot operated regulators 2 Prior Inspection Inspect the Slam Shut valve regulator p...

Страница 7: ...a handle pull the shaft into the reset position 6 With the shaft held in the reset position push the reset pin The trip mechanism will then snap into place 7 Replace the bleed cap reset cap and clear...

Страница 8: ...bottle into the Slam Shut Sense Port and apply a constant pressure above the Underpressure set point and below the Overpressure set point if applicable See Figure 5 3 Follow the Resetting the Slam Sh...

Страница 9: ...cy of the inspection and replacement of the parts depends on the severity of the service conditions and or the applicable government requirements Inspect all parts for wear and damage Replace all worn...

Страница 10: ...dry Replacement of Seals in Underpressure Assembly 1 Turn adjusting screw 2 Use 1 2 wrench to remove four cap screws from spring case with Low Trip labeled on the actuator block 3 Use 9 16 wrench to...

Страница 11: ...ccessories if applicable 2 Use 13 16 wrench to remove the four cap screws on the top plate 3 Remove the parts from the body 4 Inspect and or Replace the following seals Body Seals Qty 2 Re install dry...

Страница 12: ...owgrid Sense Line Outlet Figure 9 Pressure reducing Flowgrid with Slam Shut downstream overpressure protection Figure 10 Pressure reducing Flowgrid with Slam Shut downstream underpressure protection S...

Страница 13: ...over 60 psid 4 bar Inlet Flowgrid Sense Line Outlet Slam Shut Sense Line Outlet Outlet Inlet Flowgrid Sense Line Slam Shut Sense Line Inlet Outlet Outlet Slam Shut Sense Line Inlet Flowgrid Sense Lin...

Страница 14: ...r Seal Plate O ring Damaged sealing surface Damaged Sense Port Adapter O ring Fails External Leakage Test out of Bleed Assembly Damaged Bleed Cap O ring Damaged Bleed Stem O ring Damaged Sealing Surfa...

Страница 15: ...Mooney Flowgrid Slam Shut 1 valve Instruction Manual 13 Copyright 2021 Baker Hughes Company All rights reserved Notes...

Страница 16: ...formation The Baker Hughes logo Flowgrid Slamshut and Mooney are trademarks of Baker Hughes Company Other company names and product names used in this document are the registered trademarks or tradema...