Setup Power Fail Restarts
A common feature of well control systems is the ability to automatically restart if power is lost
while the system is running. By default, this feature is disabled in the Apollo Well Control System.
Do the following to enable the power fail restart function.
Use the up and down arrow buttons as needed to highlight Setup Power Fail Restarts. Press the
Select function button to activate the Power Fail Restarts menu.
Figure 75: Power Fail Rst Screen
Use the up and down arrow buttons to select Restarts/Allowed. Press the Select function button.
The edit screen will appear.