Copyright 2020 Baker Hughes Company. All rights reserved.
Page 154 of 277
Table 40: Setup Restart
Name
Location
Description
ManualStartOnly
Home Screen ->
Settings ->
Menu ->
ManualStartOnly
ManualStartOnly is a global
restart enable.
ManualStartOnly = True
• Drive can only be started by
pressing the Start button on the
keypad.
ManualStartOnly = False
• Drive can be started by the
keypad Start button, SCADA
start commands, Autostart on
Power Up, and restarts from
any trigger.
Global Restart
Home Screen ->
Settings ->
Menu ->
Other Initial Setup ->
Global Restart
By default, all triggers have their
Restart delay set to the Global
Restart Time. Best practice is to
set the Global Restart time to the
normal restart time on the drive
(for an ESP system, this is likely
the fluid fallback
– backspin time).
Restarts/Allowed
Trigger Info Screen
Every Stop trigger can be set to
allow restarts. Restarts/Allowed
is shown as x/y on the trigger
info screen. The y is the number
of restarts allowed. X is the
number of restarts that have been
attempted. Setting the allowed
restart to 0 disables restarts for
that trigger.
By default, all triggers have 0
allowed restarts.
Содержание Apollo 3
Страница 1: ...Copyright 2020 Baker Hughes Company All rights reserved Page 1 of 277...
Страница 46: ...Copyright 2020 Baker Hughes Company All rights reserved Page 46 of 277 Figure 20 Backspin Probes Drawing 2...
Страница 139: ...Copyright 2020 Baker Hughes Company All rights reserved Page 139 of 277 Figure 116 Murphy Switch Trigger Example 1...
Страница 266: ...Copyright 2020 Baker Hughes Company All rights reserved Page 266 of 277 Figure 227 USB Menu...
Страница 267: ......
Страница 276: ......
Страница 277: ...Index 129112 28 197705 28 197349 28 800638 28 197350 28 810280 28 197351 29...