background image

 

 

 

 

 

 

 

TECHNICAL DATA 

 

Type XS: 

Technical data  

Air heater  

XS20-450TC 

XS20-800TC 

XS20-1000TC 

XS20-1500TC 

XS20-2000TC 

Voltage  

VAC 

230 

120 

230 

120 

230 

120 

230 

120 

230 

Frequency  

Hz 

50/60 

Power 

kW 

0,45 

0,8 

1,0 

1,5 

2,0 

Electricity 

1,7 

6,7 

3,5 

8,4 

4,4 

12,5 

6,5 

16,7 

8,8 

Max. temperature 

°C / °F 

650 / 1202 

Min. air volume 

l/min 

30 

60 

75 

100 

150 

Max. pressure 

bar 

6,0 

Thermocouple 

type 

,K’ 

Weight 

kg 

0.4 

0.5 

Air inlets Ø 

mm 

Push-In plug nipple 6mm 

Blow off opening Ø 

mm 

M16 inside thread, SW 17 

Dimensions (length x Ø) 

mm 

289 x 30 

346 x 30 

Conformity symbol 

 

Protection class I 

 

 

Type PN10: 

Technical data  

Air heater  

PN10 - S 

PN10 - M 

PN10 - XL 

Voltage  

VAC 

230 

230 

400 (2 Ph) 

400 - 440 

Frequency  

Hz 

50/60 

Power 

kW 

3.3 

3.7 

4.5 

11.8 – 14.3 

Electricity 

14.4 

16.1 

11.2 

17.1 – 18.7 

Max. temperature 

°C / °F 

600 / 1112 

Min. air volume 

l/min 

420 

360 

490 

950 

Max. pressure 

bar 

10,0 

Weight Ø 

kg 

4,7 

16,5 

24,0 

Air inlets Ø (female) 

inch 

½“ 

1“ 

2“ 

Blow off opening (female) 

inch 

½“ 

1“ 

2“ 

Dimensions (L x W x H) 

mm 

360x160 

442,5 x 285 

575 x 340 

Conformity symbol 

 

Protection class I 

  

 

Type S: 

Technical data  

Air heater  

Type S21 

Type S32 

Type S36 

Voltage  

VAC 

120 

230 

120 

230 

Frequency  

Hz 

50/60 

Power 

kW 

0,55 

0,8 

1,0 

1,55 

2,0 

2,2 

2,3 

3,3 

Electricity 

4,6 

3,5 

4,4 

6,7 

8,7 

18,3 

10,0 

14,4 

Max. temperature 

°C / °F 

650 / 1202 

Min. air volume 

l/min 

150 

210 

 

230 

430 

280 

420 

Weight 

kg 

0,3 

0,4 

0,47 

Air inlets Ø 

mm 

19 

Blow off opening Ø 

mm 

13 

16 

22 

Heating pipe Ø 

mm 

21 

32 

36 / 43 

Dimensions (L x W x H) 

mm 

188 x 69,5 x 58 

228 x 69,5 x 58 

238 x 69,5 x 58 

Conformity symbol 

 

Protection class II 

 

 

Type M: 

Technical data  

Air heater  

Type M50 

Type M50L 

Voltage  

VAC 

230 

400 (2Ph) 

440 (2Ph) 

400 – 440 (2Ph) 

Frequency  

Hz 

50/60 

Power 

kW 

2,2 

3,7 

4,5 

4,1 

4,6 - 5,6 

6,1 – 7,4 

Electricity 

9,6 

16,2 

11,2 

9,2 

11,5–12,7 

15,3-16,8 

Max. temperature 

°C / °F 

650 / 1202 

Min. air volume 

l/min 

260 

360 

490 

530 

600 

830 

Weight 

kg 

0,8 

0,9 

Air inlets Ø 

mm 

38 

Blow off opening Ø 

mm 

30 

Heating pipe Ø 

mm 

50 / 65 

Dimensions (L x W x H) 

mm 

239 x 85 x 90 

278 x 85 x 90 

Conformity symbol 

 

Protection class II 

 

 
 

Содержание XS20-450TC

Страница 1: ...ult your local electricity board if necessary Device in protection class I should be earthed using a protective conductor Device in protection class II The device must be supervised when in operation...

Страница 2: ...Y 2 1 To protect the device and heating element the minimum air volume must flow Never exceed the max temperature Measured at the hottest point 3mm from the air outlet The heater must be switched off...

Страница 3: ...xperts will be pleased to help you with your problems ACCESSORIES Get the best results by using BAK accessories and spare parts Further information can be found in our brochures SERVICE AND REPAIRS Re...

Страница 4: ...h 1 2 Blow off opening female inch 1 2 Dimensions L x W x H mm 360x160 442 5 x 285 575 x 340 Conformity symbol Protection class I Type S Technical data Air heater Type S21 Type S32 Type S36 Voltage VA...

Страница 5: ...80 Frequency Hz 50 60 Power kW 5 9 7 1 8 5 7 6 9 2 10 9 11 8 14 3 17 1 17 4 21 0 25 0 Electricity A 8 5 9 4 10 2 10 9 12 0 13 2 17 1 18 7 20 5 25 1 27 6 30 1 Max temperature C F 650 1202 Min air volum...

Страница 6: ...C L1 black L2 brown L3 blue Protective conductor yellow green Type S 1 Screwed cable gland mains connection 2 Potentiometer 0 8 control cable with external control PWM 10 24VDC max cycle time 1 second...

Страница 7: ...tion 2 Screwed cable gland control cable with external control 3 Potentiometer 0 9 no potentiometer in devices without electronics and external control 4 Mounting on underside of housing M 8 useful th...

Страница 8: ...ange over contact at the clamps 1 3 see connection diagram A restart of the power stack is only possible after a reset disconnection of the tool from the mains power Measures when activating the heati...