background image

 

Unregulated DC Supply Connection 

If you want to connect a DC source that is unregulated, for example a 12V PV panel (36 Cell) without a regulator it 
must be connected to the 

Red

 Anderson Connector input labelled Solar/External Charge.  

 

The unit has a built in regulator that will stop the battery from being overcharged. 

 

Vehicle Connection 

If you want to connect a vehicle alternator output to the PowerTop connect a cable to the vehicle 12V output e.g. 
connect to ciga plug or starter battery on one end of the cable, on the other end of the cable plug into the 

Blue

 

Anderson socket labelled Vehicle charge input. The vehicle voltage must be above 13.2V to charge the PowerTop 
battery. 

 

 

 

 

25A Max

25A Max

Содержание PowerTop

Страница 1: ...1 Baintech PowerTop User Operation Manual This manual must be read in its entirety before operating the PowerTop and retained for future reference...

Страница 2: ...3 PowerTop 3 PowerTop Sockets 3 PowerTop Sides 3 Charging 4 Internal Charger 4 Fast Charging 4 Unregulated DC Supply Connection 5 Vehicle Connection 5 Load Connection 6 PowerTop Technical Information...

Страница 3: ...MPORTANT Do not block air vents on the side of the unit Ensure the PowerTop is mounted upright Ensure the PowerTop is only used in a well ventilated location Ensure the PowerTop avoids contact with wa...

Страница 4: ...en the AC plug is connected into the unit and the power switch is turned on Fast Charging If you require faster charging we recommend using a 20A maximum charger suited for Gel batteries with the foll...

Страница 5: ...built in regulator that will stop the battery from being overcharged Vehicle Connection If you want to connect a vehicle alternator output to the PowerTop connect a cable to the vehicle 12V output e...

Страница 6: ...o ensure your gear such as fridges stays connected on the roughest trips It s easy to use simply turn the plug clockwise and the locking mechanism engages ensuring all your essential gear can stay con...

Страница 7: ...nnection o Grey Load connection Protected by 50A thermal self resettable breaker Can be used for regulated output from a charger or solar charger to charge the battery Specifications Battery 100Ah 12V...