AUTOMATIC OILER
The router table has an automatic lubricating system
mounted on the back side of the left end of the gantry.
The oiler can be set for both the time intervals
between oiling cycles, and how long the pump runs
during an oiling cycle.
The oiler will pump oil for one cycle when the
machine is powered On. The interval timer (bottom
display) will then set to the full interval time and start
to count down to the next cycle. When the interval
timer counts down to zero, the pump will run and
pump oil for the number of seconds programed into
the cycle timer (top display).
The interval timer can be set from 001 to 999 minutes.
The cycle timer can be set from 001 to 999 seconds.
1. Fill the oiler with 30W oil.
2. When setting the oiler, it will start digit by digit with
the interval time, (bottom display) and then set the
cycle time (top display) digit by digit.
3. Power ON the table.
4.
Press and hold the “Set” button for 3 seconds until
the ones digit in the lower display begins to flash.
5. Use the
▲ or ▼ buttons to change the display to
the desired digit and then press the
“Set” button
until the tens digit flashes.
6. Use the
▲ or ▼ buttons to change the display to the desired digit and then press the “Set”
button until the hundreds digit flashes.
7. Use the
▲ or ▼ buttons to change the display to the desired digit and then press the “Set”
button until the ones digit of the cycle time display flashes.
8. Repeat these steps in the cycle display to set the desired oil cycle time.
9.
When the cycle time digits are set, press and hold the “Set” button for 3 seconds to lock in
the settings. The pump will run for the set cycle time.
When the oiler detects a system fault, the display will flash a fault code and sound a beeper and
the pump will stop working.
•
When the display
shows “ERO”, it means low oil. Add oil.