21
21
•
Improper connection of the equipment-grounding conductor can result in risk of electric
shock. The conductor with insulation having an outer surface that is green with or without
yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric
cord or plug is necessary, do not connect the equipment-grounding conductor to a live
terminal.
•
Check with a qualified electrician or service personnel if the grounding instructions are not
completely understood, or if in doubt as to whether the tool is properly grounded.
•
Repair or replace damaged or worn cord immediately.
Power cord connection:
1. Unlock and open the electrical enclosure door.
2. Route a power cord (customer supplied) from the
machine toward the power supply.
a. Route the power cord so that it will NOT
become entangled in the machine in any
way.
b. Route the cord to the power supply is a way
that does NOT create a trip hazard.
3. Connect the three power wires terminals L1, L2, & L3. Connect the ground wire (typically
green) to the PE block.
4. Check that the power cord has not been damaged during installation.
5. When the machine is clear of any obstruction. The main power switch may be turn ON to test
the operation. The controller will power ON, and Turn the switch OFF when the machine is
not in operation.
6. Test the vacuum pump for proper rotation. Even with correct polarity to the console, the
vacuum pump could be out of polarity and run in the wrong direction. Refer back to
“Preparing Vacuum Pump” for rotation and correction.
7. Close the electrical enclosure door. DO NOT operate with the door open.
8. Turn the switch OFF when the machine is not in operation.
WARNING:
In all cases, make certain the receptacle in question is
properly grounded. If you are not sure, have a qualified electrician check the
receptacle
.