![Baileigh Industrial PT-105HD-W Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/baileigh-industrial/pt-105hd-w/pt-105hd-w_operators-manual_3454606036.webp)
33
33
PARAMETER SETTING
In the main interface, you can get to the parameter interface by pressing the [F4] (Setup) key.
Max Cutting Speed
1500.000
mmpm
Manual Move Speed
6500.000
mmpm
G00 Move Speed
5500.000
mmpm
Demo/Back Speed
2000.000
mmpm
Marker Speed
1000.000
mmpm
Kerf Value
0.000
mm
Corner Speed (1-100)
95.00
% mmpm
Demo Run Speed
4500.00
mmpm
Cutting Type
Plasma
<->
F1
Common
F2
Flame
F3
Plasma
F5
System
F6
Import
F7
Export
F8
Save
You can set five kinds of parameters in the parameter interface:
1. Common parameters: cutting speed, manual move speed, G00 move speed, the size of kerf
gap, corner speed, cutting type, edge cut enable, hold preheat.
2. Flame parameters: all the parameters used in oxygen gas cutting
3. Plasma parameters: all the parameters used in plasma cutting
4. Margin parameters: ignition, perforation cycle parameters, dry dusting offset
5. System parameters: you can set system pulses, maximum speed limit, motor parameters and
soft limit parameters.
Common Parameters
•
Max Cutting Speed: the maximum cutting speed, unit is mm/m.
•
Manual Move Speed: the moving speed of cutting torch in manual, unit is mm/m.
•
G00 Move Speed: the cutting torch speed when G00 is executed or the cutting torch goes
back to the reference or some other occasion, unit is mm/m.
•
Demo/Back Speed: the cutting torch speed when doing a Demo from the function key, or when
using the Back function, unit is mm/m.
•
Maker Speed: This function is not used on this table system.