16/20
Instruction Manual
24V 50VA Motor control box
- Version 1.0
w w w .b ai e r- g mb h .d e
6
Initial operation
6.1.3
Configuration Switch
Switch
Description
OFF
ON
1
Operation mode
Semi-
automatic
Automatic
2
Dead man’s
control
-
Enabled
(overrides
switch #1)
3
Push & go
-
Enabled
4
Reacion to
obstruction
Reverse
Stop
5
Closing speed
Reduced
speed
Full speed
6
Low speed mode
-
Enabled
7
Setting of
maximum speed
7 OFF 8 OFF 80 %
7 ON
8 OFF 90 %
8
7 OFF 8 ON
100 %
7 ON
8 ON
60 %
Table 2 – Configuration switch
Switch 1:
Operation mode semi-automatic / automatic:
When semi-automatic mode is set the drive will not close
automatically. The potentiometer P1 is without function.
When automatic mode is set the drive closes automatically.
Switch 2:
Dead man’s control:
When dead man’s control is activated the drive will only operate,
as long as an input signal is applied. Switch 1 is inactive, when
dead man’s control is selected.
Switch 3:
Push & Go:
With push & go enabled the drive starts to move, as soon as the
door leaf is pushed manually.
Switch 4:
Reaction on obstruction:
When reverse is set the drive stops and starts to move in the
opposite direction, as soon as an obstruction is detected.
Otherwise it will stop until a new command is given. (This is only
possible in semi-automatic mode).
Switch 5:
Closing speed:
By default the closing speed is slower than the opening speed.
The closing speed can be set as fast as the opening speed, by
setting this switch to ON.
Switch 6:
Low speed mode:
When enabled, the drive will operate generally in low speed mode.
Closing and opening speed are reduced.
Switch 7:
The combination of switches 7 and 8 sets the maximum speed of
the drive. (Refer to table 2).
ON
OFF